GREEN BAY, WI —
OSHA Inspection: GQL HANDYMAN SERVICES LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GQL HANDYMAN SERVICES LLC in 932 SOUTH ERWIN STREET, GREEN BAY, WI 54301 (NAICS 238160). OSHA activity number 347868291.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GQL HANDYMAN SERVICES LLC
- Site address
- 932 SOUTH ERWIN STREET
- City
- GREEN BAY
- State
- WI
- ZIP
- 54301
- Mailing
- 806 ST GEORGE ST, GREEN BAY, WI 54302
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Dec 12, 2024
- Abate by
- Jan 13, 2025
- Penalty
- Initial $4,148 · Current $2,074 Reduced
General-duty citation text
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. On or about November 7, 2024, at the worksite located at 932 Erwin Street, Green Bay, Wisconsin; workers were performing reroofing activities on an approximately 8:12 pitch roof, without any form of fall protection, while exposed to an approximate 10'2" fall. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.
Recent events (2)
- — I (S) $2074
- — Z (S) $4148
1926.1053 B01
- Issued
- Dec 12, 2024
- Penalty
- Initial $4,148 · Current $2,074 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about November 7, 2024, at the worksite located at 932 Erwin Street, Green Bay, Wisconsin; workers were accessing and egressing a roof using a portable metal ladder that did not extend three feet above the upper landing surface.
Recent events (2)
- — I (S) $2074
- — Z (S) $4148
More inspections in this industry (NAICS 238160)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347868291.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.