Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: I2C TECHNOLOGIES, LTD.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of I2C TECHNOLOGIES, LTD. in 6004 TURNEY ROAD, CLEVELAND, OH 44125 (NAICS 238210). OSHA activity number 347869182.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch I2C Technologies, LTD. — free Get an email when a new federal OSHA severe-injury report for I2C Technologies, LTD. is published. One employer, no account, unsubscribe in one click.
Site address
6004 TURNEY ROAD
City
CLEVELAND
State
OH
ZIP
44125
Mailing
ATTN: CHRISTY KAMER 413 APPLEGROVE STREET NORTHWEST, NORTH CANTON, OH 44720
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.453 B02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 20, 2024
Penalty
Initial $3,134 · Current $1,880 Reduced
29 CFR 1926.453(b)(2)(v): A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.  a) On or about November 4, 2024, an employee installing a surveillance camera on a traffic signal mast from a LEGUAN 225 aerial lift was not protected from the fall hazard of approximately 14-feet; the employer did not ensure that the employee was protected while working from an aerial lift by use of a personal fall arrest system to include but not limited to, a harness and lanyard attached to the basket.
Recent events (2)
  • — I (S) $1880
  • — Z (S) $3134

1926.503 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 20, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.503(c): "Retraining." When the employer has reason to believe that any affected employee who has already been trained does not have the understanding and skill required by paragraph (a) of this section, the employer shall retrain each such employee. Circumstances where retraining is required include, but are not limited to, situations where:   29 CFR 1926.503(c)(2): Changes in the types of fall protection systems or equipment to be used render previous training obsolete.  a) On or about November 4, 2024, an employee installing a surveillance camera on a traffic signal mast from a LEGUAN 225 aerial lift was not protected from the fall hazard of approximately 14-feet; the employer did not ensure that the employee was retrained after the purchase of the LEGUAN 225 aerial lift to ensure the affected employees understanding of when to wear fall protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347869182.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.