CINCINNATI, OH —
OSHA Inspection: JOHN E CARRIGAN PLUMBING CO
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of JOHN E CARRIGAN PLUMBING CO in 3400 VINE ST, CINCINNATI, OH 45220 (NAICS 238220). OSHA activity number 347873853.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JOHN E CARRIGAN PLUMBING CO
- Site address
- 3400 VINE ST
- City
- CINCINNATI
- State
- OH
- ZIP
- 45220
- Mailing
- 48 WEST MCMICKEN AVENUE, CINCINNATI, OH 45202
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 2
- Ownership type
- A
Citations
14 citations on file for this inspection.
1926.251 A01
- Issued
- Mar 5, 2025
- Abate by
- Mar 25, 2025
- Penalty
- Initial $6,620 · Current $6,620
General-duty citation text
29 CFR 1926.251(a)(1):Rigging equipment for material handling shall be inspected prior to use on each shift and as necessary during its use to ensure that it is safe. Defective rigging equipment shall be removed from service. a) On or about October 30, 2024, the employer working in the Nursery Gas Pit failed to inspect the rigging chain used for rigging gas lines, that had various bent link connections and a bolt with unknown shear strength. As a result employees were exposed to crushed-by, struck-by hazards.
Recent events (2)
- — I (S) $6620
- — Z (S) $6620
1926.251 B01
- Issued
- Mar 5, 2025
- Abate by
- Mar 25, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.251(b)(1):Welded alloy steel chain slings shall have permanently affixed durable identification stating size, grade, rated capacity, and sling manufacturer. a) On or about October 30, 2024,the employer working in the Nursery Gas Pit failed to use an alloy steel chain that had a permanently affixed identification tag provided by the manufacturer. As a result employees were exposed to crushed-by, struck-by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.251 B06 II
- Issued
- Mar 5, 2025
- Abate by
- Mar 25, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.251(b)(6)(ii):The employer shall make and maintain a record of the most recent month in which each alloy steel chain sling was thoroughly inspected, and shall make such record available for examination. a) On or about October 30, 2024, the employer working in the Nursery Gas Pit failed to make and maintain a record of the most recent month in which each alloy steel chain sling was thoroughly inspected, and make such record available for examination. As a result employees rigging and hoisting gas lines out of the nursery gas pit were exposed to crushed-by, struck-by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1203 D
- Issued
- Mar 5, 2025
- Abate by
- May 1, 2025
- Penalty
- Initial $6,620 · Current $6,620
General-duty citation text
29 CFR 1926.1203(d): (d) If any employer decides that employees it directs will enter a permit space, that employer must have a written permit space program that complies with �1926.1204 implemented at the construction site. The written program must be made available prior to and during entry operations for inspection by employees and their authorized representatives. a) On or about October 30, 2024, at the AAC gas pit at the Cincinnati Zoo, John E. Carrigan Plumbing Co. failed to implement a written permit-required confined space program before directing employees to enter the confined space for the removal and replacement of gas lines. As a result, employees were exposed to a potential hazardous atmosphere, as the natural gas line had not been properly eliminated or isolated through engineering controls before entry, increasing the risk of an uncontrolled release of gas within the confined space.
Recent events (2)
- — I (S) $6620
- — Z (S) $6620
1926.1204 C
- Issued
- Mar 5, 2025
- Abate by
- May 1, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1204(c): Develop and implement the means, procedures, and practices necessary for safe permit space entry operations, including, but not limited to, the following: a) On or about October 30, 2024, at the AAC gas pit at the Cincinnati Zoo, John E. Carrigan Plumbing Co. failed to develop and implement the necessary procedures for safe entry into a permit-required confined space before directing employees to enter the space for the removal and replacement of gas lines. Specifically, the employer failed to: 1926.1204(c)(1) - Specify acceptable entry conditions prior to entry. 1926.1204(c)(3) - Isolate the permit space and physical hazards within the space, as the natural gas line had not been properly eliminated or isolated through engineering controls. 1926.1204(c)(5) - Determine whether, in the event of a ventilation system failure, monitoring procedures would detect an increase in atmospheric hazard levels in sufficient time for entrants to safely exit the permit space. 1926.1204(c)(7) - Verify that conditions within the permit space remained acceptable throughout the duration of entry, and ensure that employees were not exposed to a hazardous atmosphere unless effective personal protective equipment (PPE) was provided. 1926.1204(c)(8) - Eliminate any conditions (e.g., high pressure) that could make it unsafe to remove an entrance cover before work began. As a result, employees were exposed to hazardous atmospheric conditions and potential uncontrolled movement of pressurized gas lines, increasing the risk of serious injury.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1204 I
- Issued
- Mar 5, 2025
- Abate by
- May 1, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1204(i): (i) Develop and implement procedures for summoning rescue and emergency services (including procedures for summoning emergency assistance in the event of a failed non-entry rescue), for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and for preventing unauthorized personnel from attempting a rescue; a) On or about October 30, 2024, at the AAC gas pit at the Cincinnati Zoo, John E. Carrigan Plumbing Co. failed to develop and implement procedures for summoning rescue and emergency services, including procedures for non-entry rescue, providing emergency assistance to rescued employees, and preventing unauthorized personnel from attempting a rescue. As a result, employees entered a permit-required confined space without established procedures for responding to an emergency, including how to summon rescue services or conduct a non-entry rescue if needed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1204 J
- Issued
- Mar 5, 2025
- Abate by
- May 1, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1204(j): (j) Develop and implement a system for the preparation, issuance, use, and cancellation of entry permits as required by this standard, including the safe termination of entry operations under both planned and emergency conditions; a) On or about October 30, 2024, at the AAC gas pit at the Cincinnati Zoo, John E. Carrigan Plumbing Co. failed to develop and implement a system for the preparation, issuance, use, and cancellation of entry permits for work inside a permit-required confined space. As a result, employees entered the confined space to remove and replace gas lines without an entry permit, which documents safe entry conditions, authorized personnel, and procedures for terminating entry operations under both planned and emergency conditions.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1204 K
- Issued
- Mar 5, 2025
- Abate by
- May 1, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1204(k): (k) Develop and implement procedures to coordinate entry operations, in consultation with the controlling contractor, when employees of more than one employer are working simultaneously in a permit space or elsewhere on the worksite where their activities could, either alone or in conjunction with the activities within a permit space, foreseeably result in a hazard within the confined space, so that employees of one employer do not endanger the employees of any other employer; a) On or about October 30, 2024, at the AAC gas pit at the Cincinnati Zoo, John E. Carrigan Plumbing Co. failed to develop and implement procedures to coordinate entry operations with the controlling contractor while multiple employers had employees working simultaneously at the site. As a result, the activities within the permit-required confined space, including the removal and replacement of gas lines, were not coordinated to ensure that the actions of one employer did not create hazards for employees of another employer, increasing the risk of exposure to uncontrolled hazards within the confined space.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1204 L
- Issued
- Mar 5, 2025
- Abate by
- May 1, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1204(l): (l) Develop and implement procedures (such as closing off a permit space and canceling the permit) necessary for concluding the entry after entry operations have been completed; a) On or about October 30, 2024, at the AAC gas pit at the Cincinnati Zoo, John E. Carrigan Plumbing Co. failed to develop and implement procedures for concluding entry operations after work inside the permit-required confined space was completed, including closing off the space and canceling the entry permit. As a result, there were no documented procedures to ensure the permit space was properly secured after entry operations ended.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1205 A
- Issued
- Mar 5, 2025
- Abate by
- May 1, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1205(a): (a) Before entry is authorized, each entry employer must document the completion of measures required by �1926.1204(c) by preparing an entry permit. a) On or about October 30, 2024, at the AAC gas pit at the Cincinnati Zoo, John E. Carrigan Plumbing Co. failed to document the completion of required entry measures before authorizing employees to enter the permit-required confined space for the removal and replacement of gas lines. As a result, employees entered the confined space without an entry permit, which serves to verify that necessary safety measures, including hazard isolation and atmospheric monitoring, had been completed prior to entry.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1204 H
- Issued
- Mar 5, 2025
- Abate by
- May 1, 2025
- Penalty
- Initial $6,620 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1204(h): (h) Designate each person who is to have an active role (as, for example, authorized entrants, attendants, entry supervisors, or persons who test or monitor the atmosphere in a permit space) in entry operations, identify the duties of each such employee, and provide each such employee with the training required by �1926.1207; a) On or about October 30, 2024, at the AAC gas pit at the Cincinnati Zoo, John E. Carrigan Plumbing Co. failed to designate individuals responsible for active roles in the permit-required confined space entry, including authorized entrants, attendants, entry supervisors, and personnel responsible for atmospheric testing and monitoring. Additionally, the employer failed to identify the duties of each individual involved in entry operations and did not provide the required training for employees entering the confined space. As a result, employees entered a permit-required confined space without clear role assignments or the necessary training to recognize and respond to potential hazards, increasing the risk of exposure to hazardous atmospheric conditions and uncontrolled gas line movement.
Recent events (2)
- — I (S) $0
- — Z (S) $6620
1926.1207 A
- Issued
- Mar 5, 2025
- Abate by
- May 1, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1207(a): The employer must provide training to each employee whose work is regulated by this standard, at no cost to the employee, and ensure that the employee possesses the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under this standard. This training must result in an understanding of the hazards in the permit space and the methods used to isolate, control or in other ways protect employees from these hazards, and for those employees not authorized to perform entry rescues, in the dangers of attempting such rescue a) On or about October 30, 2024, at the AAC gas pit at the Cincinnati Zoo, John E. Carrigan Plumbing Co. failed to provide training to employees performing work inside a permit-required confined space. As a result, employees entered the confined space without the necessary understanding, knowledge, and skills to recognize hazards, implement control measures, or safely perform their assigned duties, including the methods used to isolate and control hazards within the space.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1208 B
- Issued
- Mar 5, 2025
- Abate by
- May 1, 2025
- Penalty
- Initial $6,620 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1208(b): (b) Properly use equipment as required by �1926.1204(d); a) On or about October 30, 2024, at the AAC gas pit at the Cincinnati Zoo, John E. Carrigan Plumbing Co. failed to ensure that atmospheric monitoring equipment used to evaluate the permit-required confined space was properly calibrated before use. Specifically, the four-gas meters provided by the Cincinnati Zoo had not been bump tested to verify their accuracy before employees entered the confined space for gas line removal and replacement. As a result, employees relied on unverified atmospheric monitoring data, increasing the risk of undetected hazardous atmospheric conditions within the confined space.
Recent events (2)
- — I (S) $0
- — Z (S) $6620
1904.39 A02
- Issued
- Mar 5, 2025
- Abate by
- Mar 25, 2025
- Penalty
- Initial $4,729 · Current $500 Reduced
General-duty citation text
29 CFR 1904.39(a)(2):Basic Requirement. Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA. a) On or about October 30, 2024, the employer failed to report within the required 24hr time period an in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident.
Recent events (2)
- — I (O) $500
- — Z (O) $4729
More inspections at John E Carrigan Plumbing CO
View John E Carrigan Plumbing CO's full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347873853.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.