SAN DIEGO, CA —
OSHA Inspection: SOUTHCOAST WELDING & MANUFACTURING INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SOUTHCOAST WELDING & MANUFACTURING INC in 32ND STREET SAN DIEGO NAVAL BASE USS STERETT (DDG-104) PIER 7, SAN DIEGO, CA 92136 (NAICS 336611). OSHA activity number 347875577.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOUTHCOAST WELDING & MANUFACTURING INC
- Site address
- 32ND STREET SAN DIEGO NAVAL BASE USS STERETT (DDG-104) PIER 7
- City
- SAN DIEGO
- State
- CA
- ZIP
- 92136
- Mailing
- 2591 FAIVRE STREET #1, CHULA VISTA, CA 91911
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 60
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.334 A01
- Issued
- Jan 22, 2025
- Abate by
- Feb 18, 2025
- Penalty
- Initial $16,550 · Current $10,758 Reduced
General-duty citation text
29 CFR 1910.334(a)(1): Portable electric equipment was not handled in a manner which would not cause damage: Pier 7, USS Sterett (DDG-104), AUX 2: On November 7, 2024, a powered 50 foot, 440 volt, 30 amp, cable was disconnected and torn out of the female housing. This portable cable was not handled in a manner which would not cause damage. Employee(s) were exposed to electrical shock hazard(s).
Recent events (2)
- — I (S) $10757.5
- — Z (S) $16550
More inspections at Southcoast Welding & Manufacturing INC
View Southcoast Welding & Manufacturing INC's full OSHA safety record →
More inspections in this industry (NAICS 336611)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347875577.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.