MERRILL, WI —
OSHA Inspection: MMP OF MERRILL, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MMP OF MERRILL, INC. in 905 SOUTH STATE STREET, MERRILL, WI 54452 (NAICS 332119). OSHA activity number 347878811.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MMP OF MERRILL, INC.
- Site address
- 905 SOUTH STATE STREET
- City
- MERRILL
- State
- WI
- ZIP
- 54452
- Mailing
- PO BOX 207, MERRILL, WI 54452
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332119
- Employees
- 63
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 D
- Issued
- Dec 27, 2024
- Abate by
- Jan 13, 2025
- Penalty
- Initial $6,857 · Current $4,800 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about November 9, 2024, at a workplace located at S 905 State Street, Merrill, Wisconsin in the Ring Department; employees were exposed to machine hazards associated with the pinch point created by the downward motion of the press when they engaged in servicing and/or maintenance activities on the RF15 - Auto Double Rail Welder. The employer did not ensure that employees implemented energy control application steps or equivalent protective measures prior to allowing them to troubleshooting. The machine was not deenergized prior to the employee engaging in the servicing / maintenance activity. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.
Recent events (2)
- — I (S) $4799.9
- — Z (S) $6857
1910.147 F01 II
- Issued
- Dec 27, 2024
- Abate by
- Jan 13, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(1)(ii): Remove employees from the machine or equipment area in accordance with paragraph (e)(2) of this section: On or about November 9, 2024, at a workplace located at 905 South State Street, Merrill, Wisconsin in the Rings Department; while troubleshooting and testing the RF-15 Auto Double Rail Welder machine, employees were not removed from the equipment prior to the machine being activated to prevent exposure to pinch point and/or crushing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Dec 27, 2024
- Abate by
- Feb 5, 2025
- Penalty
- Initial $6,857 · Current $4,800 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.; On or about November 4, 2024, at a workplace located at 905 S State Street, Merrill, Wisconsin in the Tool Room; the unused portion of the blade on the W.F. Wells horizontal bandsaw were not guarded to prevent inadvertent contact with the rotating saw blade.
Recent events (2)
- — I (S) $4799.9
- — Z (S) $6857
1910.212 A03 II
- Issued
- Dec 27, 2024
- Abate by
- Feb 28, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle; a) On or about November 14, 2024, at a workplace located at 905 S State Street, Merrill, Wisconsin in the Ring Department; an employee operating the Doubles spot welder was exposed to the unguarded hazardous downward clamp movement of the operation. b) On or about November 14, 2024, at a workplace located at 905 S State Street, Merrill, Wisconsin in the Press Department; an employee operating the drill press was not protected from the rotating drill bit while countersinking holes into metal brackets. c) On or about November 19, 2024, at a workplace located at 905 S State Street, Merrill, Wisconsin in the Ring Department; the RF-02 automatic ring machine stations were not guarded to prevent employee exposure to pinch point hazard created by the downward and cutting motion of the machine. d) On or about November 19, 2024, at a workplace located at 905 S State Street, Merrill, Wisconsin in the Ring Department; the RF-05 automatic ring machine stations was not guarded to prevent employee exposure to the pinch point hazard created by the downward motion of the machine. e) On or about November 19, 2024, at a workplace located at 905 S State Street, Merrill, Wisconsin in the Ring Department; the Banner, asset 224 automatic ring machine stations was not guarded to prevent employee exposure to the pinch point hazard created by the downward motion of the press. f) On or about November 19, 2024, at a workplace located at 905 S State Street, Merrill, Wisconsin in the Tool Room; the powered Die Handler was not guarded to prevent employee exposure to the pinch point hazard created by the downward motion of the top of the machine.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 II
- Issued
- Dec 27, 2024
- Abate by
- Feb 5, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection: On or about November 14, 2024, at a workplace located at 905 South State Street, Merrill, Wisconsin; the employer did not certify the completion of a periodic inspection of the energy control procedures to ensure an accurate procedure and that employees were familiar with their responsibilities under the procedures.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332119)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347878811.