Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CHARTER AARROWCAST

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CHARTER AARROWCAST in 2900 E RICHMOND STREET, SHAWANO, WI 54166 (NAICS 331511). OSHA activity number 347880833.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Charter Aarrowcast — free Get an email when a new federal OSHA severe-injury report for Charter Aarrowcast is published. One employer, no account, unsubscribe in one click.
Establishment
CHARTER AARROWCAST
Site address
2900 E RICHMOND STREET
City
SHAWANO
State
WI
ZIP
54166
Mailing
2900 E RICHMOND STREET, SHAWANO, WI 54166
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
220
Ownership type
A

3 citations on file for this inspection.

1910.134 A02

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Mar 14, 2025
Abate by
Apr 18, 2025
Penalty
Initial $6,632 · Current $4,642 Reduced

Hazardous substances 9135

29 CFR  1910.134(a)(2): A respirator shall be provided to each employee when such equipment is necessary to protect the health of such employee. The employer shall provide the respirators which are applicable and suitable for the purpose intended. The employer shall be responsible for the establishment and maintenance of a respiratory protection program, which shall include the requirements outlined in paragraph (c) of this section. The program shall cover each employee required by this section to use a respirator.  a) On or about January 30, 2025, at the establishment located at 2900 East Richmond Street, Shawano, Wisconsin; the employer did not provide a respirator to an employee when such equipment was necessary to protect the health of such employee. One Furnace Operator working on Furnace 5 was overexposed to the total dust fraction of particulate not otherwise regulated (PNOR), which exceeded the 8-hour time-weighted average (TWA) permissible exposure limit (PEL) of 15 milligrams per cubic meter (mg/m3), and was not provided and required to wear a respirator.
Recent events (2)
  • — I (O) $4642.2
  • — Z (S) $6632

1910.1000 A02

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Mar 14, 2025
Abate by
Apr 18, 2025
Penalty
Initial $0 · Current $0

Hazardous substances 9135

29 CFR 1910.1000(a)(2):  An employee's exposure to any substance in Table Z-1, the exposure limit of which is not preceded by a "C", shall not exceed the 8-hour Time Weighted Average given for that substance any 8-hour work shift of a 40-hour work week.  b) On or about January 30, 2025, at the establishment located at 2900 East Richmond Street, Shawano, Wisconsin; a Furnace Operator was exposed to an 8-hour TWA of 19.3 mg/m3 of the total dust fraction of particulate not otherwise regulated (PNOR), approximately 1.29 times the PEL of 15 mg/m3. The exposure level was derived from one sample collected over a 459 minute sampling period with zero exposure assumed for the unsampled period of 21 minutes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1000 E

Deleted Serious Gravity 1 2 instances 2 exposed
Issued
Mar 14, 2025
Abate by
Apr 18, 2025
Penalty
Initial $0 · Current $0

Hazardous substances 9135

29 CFR  1910.1000(e): To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.  At the establishment located at 2900 East Richmond Street, Shawano, Wisconsin; the employer did not determine and implement feasible administrative or engineering controls to achieve compliance with paragraph (a) of 29 CFR 1910.1000, exposing employees to chemical hazards in the following instances:  a) On or about November 14, 2024, a Grinder was exposed to an 8-hour time-weighted average (TWA) of 32.9 milligrams per cubic meter (mg/m3) of the total dust fraction of particulate not otherwise regulated (PNOR), approximately 2.19 times the permissible exposure limit (PEL) of 15 mg/m3. The exposure level was derived from one sample collected over a 173 minute sampling period with zero exposure assumed for the unsampled period of 307 minutes. b) On or about January 30, 2025, a Furnace Operator was exposed to an 8-hour TWA of 19.3 mg/m3 of the total dust fraction of PNOR, approximately 1.29 times the PEL of 15 mg/m3. The exposure level was derived from one sample collected over a 459 minute sampling period with zero exposure assumed for the unsampled period of 21 minutes.  Applicable engineering or administrative controls may include, but are not limited to the following:  1) Conduct thorough air studies in the Operator work areas to verify PNOR sources, existing controls, employee proximity to sources, and job tasks which expose employees in order to determine the most effective engineering and administrative controls. 2) Utilize local exhaust ventilation system to remove dust from the breathing zone of employees. 3) Reinforce initial trailing to employees on controlling and aiming the swarth and aiming the swarth (grinding sparks trail from handheld grinding tools) into the ventilation capture hoods as often as possible with periodic audits of swarth control, periodic refresher training and active enforcement from Lead employees and department Supervisors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Charter Aarrowcast's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347880833.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.