Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: D&E CONSTRUCTION AND REMODELING, INC.

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of D&E CONSTRUCTION AND REMODELING, INC. in 156 JACKS WAY, CAMDEN, DE 19934 (NAICS 238160). OSHA activity number 347881740.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D&E Construction and Remodeling, INC. for free Get an email when a new federal OSHA severe-injury report for D&E Construction and Remodeling, INC. is published. One employer, no account, unsubscribe in one click.
Site address
156 JACKS WAY
City
CAMDEN
State
DE
ZIP
19934
Mailing
511 MONMOUTH STREET, TRENTON, NJ 08609
Inspection type
Programmed Related (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
Private (A)

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 21, 2025
Penalty
Initial $4,965 · Current $3,476 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a) 156 Jacks Way, Camden-Wyoming, DE 19934; on or about November 15, 2024, employees exposed to falls approximately 23 feet above the next lower level while performing roofing replacement work on an existing single-family home without any means of fall protection.
Recent events (2)
  • · I (S) $3475.5
  • · Z (S) $4965

1926.1053 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 21, 2025
Penalty
Initial $4,965 · Current $3,476 Reduced
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) 156 Jacks Way, Camden-Wyoming, DE 19934; on or about November 15, 2024, CSHO viewed employees accessing upper landings/surfaces approximately 23 feet above the next lower grade without the ladder extending at least 3 feet above the contact point to conduct roof replacement work.
Recent events (2)
  • · I (S) $3475.5
  • · Z (S) $4965

View D&E Construction and Remodeling, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347881740.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.