OSHA Inspection: MIDSUN GROUP INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MIDSUN GROUP INC. in 2385 CAMPBELL ROAD, SIDNEY, OH 45365 (NAICS 238990). OSHA activity number 347883571.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Midsun Group INC. — free Get an email when a new federal OSHA severe-injury report for Midsun Group INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MIDSUN GROUP INC.
Site address
2385 CAMPBELL ROAD
City
SIDNEY
State
OH
ZIP
45365
Mailing
135 REDSTONE ST., SOUTHINGTON, CT 06489
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 2 instances 3 exposed
Issued
Apr 28, 2025
Abate by
Jun 16, 2025
Penalty
Initial $11,585 · Current $5,792 Reduced
29 CFR  1926.21(b)(2):The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:  Midsun Group, Inc. at the jobsite located at 2385 Campbell Road in Sidney, Ohio;  Instance B   On or about November 14, 2024, the employer did not ensure each employee was trained in the recognition and avoidance of unsafe workplace conditions, and the applicable regulations to control or eliminate hazards. Employees engaged in the refurbishment of the middle metal clad switch gear cabinet were exposed to falls of approximately eight feet in that the fall arrest systems worn by employees were rigged in a manner that would not prevent a free fall of more than six feet, nor contact any lower level.
Recent events (2)
  • — I (S) $5792
  • — Z (S) $11585

1926.502 D16 III

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 28, 2025
Abate by
May 9, 2025
Penalty
Initial $11,585 · Current $0 Reduced
29 CFR  1926.502(d)(16)(iii):Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:  Midsun Group, Inc. at the jobsite located at 2385 Campbell Road in Sidney, Ohio;  On or about November 14, 2024, the employer did not ensure that the personal fall arrest systems utilized by employees were rigged such that an employee can neither free fall more than six feet, nor contact any lower level.   Employees engaged in the refurbishment of the top of the middle metal clad switch gear cabinet were exposed to falls of approximately eight feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11585

1926.416 A01

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Apr 28, 2025
Abate by
May 9, 2025
Penalty
Initial $11,585 · Current $0 Reduced
29 CFR  1926.416(a)(1):The employer permitted employees to work in close proximity to energized, unguarded, and ungrounded electric power circuits that the employee could contact in the course of their work:   Midsun Group, Inc. at the jobsite located at 2385 Campbell Road in Sidney, Ohio;  On or about November 14, 2024, the employer did not ensure employees were protected from coming into contact with electrical power circuits through the course of work. Employees engaged in the refurbishment of the middle metal clad switch gear cabinet were exposed to electrical shock hazards associated with contact with 12kV in that the BK-2M Bus was not deenergized and grounded or effectively guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11585

1926.416 A03

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Apr 28, 2025
Abate by
May 9, 2025
Penalty
Initial $11,585 · Current $0 Reduced
29 CFR  1926.416(a)(3):The employer began work without determining if employees could contact any part of an energized circuit and did not post warning signs and advise employees of the location of the circuit, hazards, and protective measures they need to take:  Midsun Group, Inc. at the jobsite located at 2385 Campbell Road in Sidney, Ohio;  On or about November 14, 2024, the employer did not ensure through direct observation or by instrumentation whether any part of an energized electrical power circuit was located in a manner to which a person, tool, or machine could come into physical or electrical contact. Employees engaged in the refurbishment of the middle metal clad switch gear cabinet were exposed to electrical shock hazards associated with contact with 12kV in that the electrical energy feeding the BK-2M Bus was not verified to be isolated.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11585

View Midsun Group INC.'s full OSHA safety record →