OSHA Inspection: 5TH GEN SIGNS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of 5TH GEN SIGNS in 70 COMMERCIAL STREET, LEWISTON, ME 04240 (NAICS 339950). OSHA activity number 347887069.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch 5TH GEN Signs — free Get an email when a new federal OSHA severe-injury report for 5TH GEN Signs is published. One employer, no account, unsubscribe in one click.
Establishment
5TH GEN SIGNS
Site address
70 COMMERCIAL STREET
City
LEWISTON
State
ME
ZIP
04240
Mailing
647 PLEASANT STREET, LEWISTON, ME 04240
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339950
Employees
15
Ownership type
A

12 citations on file for this inspection.

1910.107 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 12, 2025
Penalty
Initial $4,729 · Current $2,365 Reduced
29 CFR 1910.107(b)(1): The spray booth�was not�substantially constructed�of steel,�concrete, masonry, or other non-combustible material:  Temporary Spray Booth - The spray booth was not constructed of a non-combustible material.
Recent events (2)
  • — I (S) $2364.5
  • — Z (S) $4729

1910.107 C04

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 12, 2025
Penalty
Initial $6,620 · Current $3,000 Reduced
29 CFR 1910.107(c)(4): Electrical wiring and equipment did not conform to the provisions of this paragraph and were not otherwise in accordance with subpart S of this part:  Temporary Spray Booth - Installed electrical wiring methods and equipment were not intrinsically safe or rated for the appropriate hazardous location, in the following instances:  a) AGILIGHT pro premium LED lighting, model #LS-PRO4-24-HO-65K-300-A, and associated wiring connections.  b) Constant voltage output LED driver, model #LV100-24N-UNV-L.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $6620

1910.107 D05

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 12, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.107(d)(5): Electric motors driving exhaust fans for spray booths were located inside the booth(s) and did not meet the requirements of subpart S of this part:  Temporary Spray Booth - A Maxx Air Pro Flex, model BF42BDPETSC, exhaust fan/motor was used inside the spray booth which was not intrinsically safe or rated for the hazardous location.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C01

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 12, 2025
Penalty
Initial $6,620 · Current $3,000 Reduced
29 CFR 1910.134(c)(1): The employer did not establish and/or implement a written respiratory protection program with required worksite-specific procedures in a workplace where respirator use is required:            Facility - The employer did not implement a written respiratory protection program for employees who were required to wear respirators while spray painting.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $6620

1910.134 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 12, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide employees with a medical evaluation to determine their ability to use a respirator before employees were required to use a respirator:  Facility - The employer did not provide a medical evaluation to employees required to wear a 3M half-face respirator for spray painting.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 12, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that employees required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  Facility - The employer did not provide a fit test for employees required to wear a 3M half-face respirator for spray painting.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 G01 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 12, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face:   Paint Booth - An employee, involved in spray painting operations, utilized a 3M half-face respirator that had facial hair that came between the sealing surface of the facepiece and the face.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 12, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and/or damaging chemicals:  Paint Storage Room - Respirators were stored by hanging them on the wall, exposing them to damaging chemicals.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 12, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k): The employer did not provide initial, and annual, comprehensive and understandable respirator training to employees who were required to use a respirator:  Facility - Employees wearing respirators were not provided respiratory protection training.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 1 1 instance 7 exposed
Issued
Feb 12, 2025
Penalty
Initial $2,837 · Current $2,039 Reduced
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazardous chemical was introduced into their work area:   Facility - Employees were not provided training on hazardous chemicals in their work area prior to the time of their initial assignment.
Recent events (2)
  • — I (S) $2038.5
  • — Z (S) $2837

1910.107 G07

Other-than-serious 2 instances 3 exposed
Issued
Feb 12, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(7): No smoking sign(s) in large letters, on contrasting background color, were not conspicuously posted at all spraying areas and/or paint storage areas:  Facility - A "no smoking" sign was not posted in the area of the temporary carport spray booth or the permanent spray booth/ paint storage area.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L06

Other-than-serious 1 instance 3 exposed
Issued
Feb 12, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by paragraph (l) through a certification that included the name of the operator, date of the training, date of evaluation, and the identity of the person(s) performing the training or evaluation:  Facility - Certifications were not maintained by the employer for employees who had received powered industrial truck training.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View 5TH GEN Signs's full OSHA safety record →