Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A & E ROOFING AND SIDING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A & E ROOFING AND SIDING, INC. in 420 WASHINGTON ST, WESTMONT, IL 60559 (NAICS 238160). OSHA activity number 347890915.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A & E Roofing and Siding, INC. — free Get an email when a new federal OSHA severe-injury report for A & E Roofing and Siding, INC. is published. One employer, no account, unsubscribe in one click.
Site address
420 WASHINGTON ST
City
WESTMONT
State
IL
ZIP
60559
Mailing
325 MARSHALL AVE., AURORA, IL 60506
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

5 citations on file for this inspection.

1926.416 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 19, 2024
Abate by
Jan 6, 2025
Penalty
Initial $8,873 · Current $8,873
29 CFR  1926.416(a)(1): No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.  On or about November 20, 2024 the employer did not deenergizing and ground or effectively guard an  energized residential  electrical service drop, exposing an employee to 240 volts.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $8873
  • — Z (S) $8873

1926.502 D17

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Dec 19, 2024
Abate by
Jan 6, 2025
Penalty
Initial $8,873 · Current $0 Reduced
29 CFR  1926.502(d)(17): The attachment point of the body belt shall be located in the center of the wearer's back. The attachment point of the body harness shall be located in the center of the wearer's back near shoulder level, or above the wearer's head.  On or about November 20, 2024, an employee performing residential roofing operations attached lifelines to the front of their  Personal Fall Arrest Systems, exposing the employee to a fall hazards.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $8873

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 19, 2024
Abate by
Jan 6, 2025
Penalty
Initial $17,747 · Current $10,000 Reduced
29 CFR  1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  On or about November 20, 2024, an employee performing residential roofing operations was not protected from a fall, exposing the employee to a fall of 11 feet.  A & E Roofing and Siding, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(10), which was contained in OSHA inspection number 1745262, citation number 1, item number 1 and was affirmed as a final order on June 4, 2024, with respect to a workplace located at 1000 E Rand Road Arlington Heights, IL 60004.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $10000
  • — Z (R) $17747

1926.502 D15

Other-than-serious 1 instance 1 exposed
Issued
Dec 19, 2024
Abate by
Jan 6, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment shall be independent of any anchorage being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee attached, or shall be designed, installed, and used as follows:  On or about November 20, 2024, roof anchors were installed with two lifelines attached and not capable of supporting 5,000 pounds per employee.    Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.502 D21

Other-than-serious 1 instance 1 exposed
Issued
Dec 19, 2024
Abate by
Jan 6, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.502(d)(21): Personal fall arrest systems shall be inspected prior to each use for wear, damage and other deterioration, and defective components shall be removed from service.  On or about November 20, 2024 a personal fall arrest system was not inspected prior to uses, exposing employees to the hazards associated with using damaged fall protection equipment.   Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View A & E Roofing and Siding, INC.'s full OSHA safety record →