On , OSHA opened a planned safety inspection of FLACK STEEL LLC DBA FLACK GLOBAL METALS in 17904 EAST 3100 NORTH ROAD, GRIDLEY, IL 61744 (NAICS 332999). OSHA activity number 347891137.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Flack Steel LLC DBA Flack Global Metals — free Get an email when a new federal OSHA severe-injury report for Flack Steel LLC DBA Flack Global Metals is published. One employer, no account, unsubscribe in one click.
Site address
17904 EAST 3100 NORTH ROAD
City
GRIDLEY
State
IL
ZIP
61744
Mailing
17904 EAST 3100 NORTH ROAD, GRIDLEY, IL 61744
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
32
Ownership type
A

8 citations on file for this inspection.

1910.29 B01

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Mar 18, 2025
Abate by
Apr 16, 2025
Penalty
Initial $8,511 · Current $0 Reduced
29 CFR 1910.29(b)(1): The employer did not ensure that guardrail systems met the requirement that the top edge height of top rails, or equivalent guardrail system members, that are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface:    On or about November 20, 2024, an employee working from the raised platform attached to the 48-inch mill located in Building B was exposed to falling onto the mill because two sections of the top rail located on the mill side were approximately 36 inches high.
Recent events (2)
  • — I (O) $0
  • — Z (S) $8511

1910.29 B02 I

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Mar 18, 2025
Abate by
Apr 16, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.29(b)(2)(i): The employer did not ensure that guardrails met the requirement that midrails that are installed at a height midway between the top edge of the guardrail system and the walking-working surface:   On or about November 20, 2024, an employee working from the raised platform attached to the 48-inch mill located in Building B was exposed to a fall hazard of approximately 4'-6" because the guardrail located opposite of the mill did not contain a midrail.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 18, 2025
Abate by
Apr 30, 2025
Penalty
Initial $10,641 · Current $6,385 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On or about November 20, 2024, employees performing servicing and maintenance activities, including setting up the Bradbury Hemmer, were exposed to hazardous stored energy, including but not limited to, electrical and gravity, and the employer did not develop, document and utilize procedures for employees in accordance with the standard.
Recent events (2)
  • — I (S) $6384.5
  • — Z (S) $10641

1910.147 C07 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 18, 2025
Abate by
Apr 30, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:  On or about November 20, 2024, employees performing servicing and maintenance activities, including setting up the Bradbury Hemmer, were exposed to hazardous stored energy, including but not limited to, electrical and gravity, and the employer did not ensure employees were trained in accordance with the standard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 F03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 18, 2025
Abate by
Apr 30, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft, department, or other group:  On or about November 20, 2024, employees performing servicing and maintenance activities, including setting up the Bradbury Hemmer, were exposed to hazardous stored energy, including electrical and gravity, and the employer did not ensure a group lockout procedure was used.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 F03 II D

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 18, 2025
Abate by
Apr 30, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment:  On or about November 20, 2024, employees performing servicing and maintenance activities, including setting up the Bradbury Hemmer, were exposed to hazardous stored energy, including but not limited to, electrical and gravity, and the employer did not ensure locks were used by each employee to isolate and control the energy sources.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II

Serious Gravity 5 10 instances 1 exposed
Issued
Mar 18, 2025
Abate by
Jun 30, 2025
Penalty
Initial $10,641 · Current $6,385 Reduced
29 CFR  1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):   On or about November 20, 2024, an employee performing servicing and maintenance activities on equipment was exposed to hazardous stored energy, including but not limited to, electrical and gravity, and the energy control procedures did not include specific procedural steps for testing the equipment to verify the effectiveness of the lockout devices:  The machine specific written procedures for the:  a. Mill 1 did not include steps for testing and verifying that all electrical and hydraulic energy sources had been dissipated and effectively controlled.  b. 48" Mill did not include steps for testing and verifying that all electrical and pneumatic energy sources had been dissipated and effectively controlled.  c. Stolarczyk Re-Coiler did not include steps for testing and verifying that all electrical and pneumatic energy sources had been dissipated and effectively controlled.  d. Schlebach CTL did not include steps for testing and verifying that all electrical energy sources had been dissipated and effectively controlled.  e. Side Shear did not include steps for testing and verifying that all electrical and pneumatic energy sources had been dissipated and effectively controlled.  f. Back Shear did not include steps for testing and verifying that all electrical and hydraulic energy sources had been dissipated and effectively controlled.  g. Mill 5 did not include steps for testing and verifying that all electrical and hydraulic energy sources had been dissipated and effectively controlled.  h. The Jorns Normaline folder lockout procedures did not include step for testing and verifying that electrical and hydraulic energy sources had been dissipated and effectively controlled.  i. The Thalman folder lockout procedures did not include step for testing and verifying that electrical and hydraulic energy sources had been dissipated and effectively controlled.  j. FJ-10 Mill lockout procedures did not include step for testing and verifying that electrical and pneumatic energy sources had been dissipated and effectively controlled.
Recent events (2)
  • — I (S) $6384.5
  • — Z (S) $10641

1910.212 A03 II

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 18, 2025
Abate by
Jun 30, 2025
Penalty
Initial $14,895 · Current $8,937 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded:  On or about November 20, 2024, an employee was exposed to amputation hazards while operating the single folder machine because the point of operation was not guarded.
Recent events (3)
  • — P (S) $8937
  • — I (S) $8937
  • — Z (S) $14895