EL PASO, TX —
OSHA Inspection: EL PASO A.R.C. ELECTRIC, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EL PASO A.R.C. ELECTRIC, INC. in INTERSTATE 10 EAST EXIT 30, EL PASO, TX 79915 (NAICS 238210). OSHA activity number 347894032.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EL PASO A.R.C. ELECTRIC, INC.
- Site address
- INTERSTATE 10 EAST EXIT 30
- City
- EL PASO
- State
- TX
- ZIP
- 79915
- Mailing
- 8010 NORTH LOOP DRIVE, EL PASO, TX 79915
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 12
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.651 I03
- Issued
- Jan 17, 2025
- Abate by
- Feb 14, 2025
- Penalty
- Initial $5,675 · Current $5,675
General-duty citation text
29 CFR 1926.651(i)(3): Sidewalks, pavements, or appurtenant structures had been undermined and a support system or another method was not provided to protect employees from the possible collapse of such structures: On or about November 21, 2024, approximately middle of jobsite, employees were conducting highway construction activities inside an excavation where the pavement, road, etc. had been undermined and not supported.
Recent events (2)
- — I (S) $5675
- — Z (S) $5675
1926.651 J01
- Issued
- Jan 17, 2025
- Abate by
- Feb 14, 2025
- Penalty
- Initial $3,783 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(j)(1): Adequate protection was not provided to protect employees from loose rock or soil that could pose a hazard by falling or rolling from an excavation face: On or about November 21, 2024, approximately middle of the jobsite, employees did not have adequate protection from loose rock or soil while conducting highway construction activities inside an excavation.
Recent events (2)
- — I (S) $0
- — Z (S) $3783
1926.652 A01
- Issued
- Jan 17, 2025
- Abate by
- Feb 14, 2025
- Penalty
- Initial $5,675 · Current $0 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). On or about November 21, 2024, inside excavation, employee(s) did not have an adequate form of cave in protection while performing highway construction activities.
Recent events (2)
- — I (S) $0
- — Z (S) $5675
1926.1053 B04
- Issued
- Jan 17, 2025
- Abate by
- Feb 14, 2025
- Penalty
- Initial $5,675 · Current $5,675
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: On or about November 21, 2024, south of excavation, employees were conducting highway construction activities were using an A-Frame ladder for purposes other than the purpose for which it was designed.
Recent events (2)
- — I (S) $5675
- — Z (S) $5675
More inspections at EL Paso A.R.C. Electric, INC.
View EL Paso A.R.C. Electric, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347894032.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.