Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HD DISTRIBUTION LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of HD DISTRIBUTION LLC in 3147 NORTH CENTURY STREET, COLORADO SPRINGS, CO 80907 (NAICS 424590). OSHA activity number 347894859.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch HD Distribution LLC — free Get an email when a new federal OSHA severe-injury report for HD Distribution LLC is published. One employer, no account, unsubscribe in one click.
Establishment
HD DISTRIBUTION LLC
Site address
3147 NORTH CENTURY STREET
City
COLORADO SPRINGS
State
CO
ZIP
80907
Mailing
3147 NORTH CENTURY STREET, COLORADO SPRINGS, CO 80907
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424590
Employees
20
Ownership type
A

5 citations on file for this inspection.

1910.134 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 19, 2025
Abate by
Mar 19, 2025
Penalty
Initial $9,931 · Current $5,959 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  (a) 3147 Century St, Colorado Springs, CO 80907: On or about November 19, 2024, and at times prior, the employer did not establish and implement a written respiratory protection program as required by this standard. Employees were required to use half-face elastomeric respirators and handle chemicals with respiratory hazards including, but not limited to, heptane and ethanol.
Recent events (2)
  • — I (S) $5958.6
  • — Z (S) $9931

1910.134 F01

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 19, 2025
Abate by
Mar 19, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  (a) 3147 Century St, Colorado Springs, CO 80907: On or about November 19, 2024, and at times prior, the employer did not ensure that employees were fit tested prior to required use of tight-fitting respirators. Employees were required to use half face elastomeric respirators when handling chemicals with respiratory hazards including, but not limited to, heptane and ethanol.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H01

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 19, 2025
Abate by
Mar 19, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(1): Respirators were not cleaned and disinfected using the procedures in Appendix B-2 of 29 CFR 1910.134 or equivalent procedures recommended by the respirator manufacturer:  (a) 3147 Century St, Colorado Springs, CO 80907: On or about November 19, 2024, and at times prior, the employer did not ensure that respirators were cleaned and disinfected using the procedures required by this standard. Employees used ethanol containing heptane to clean respirator facepieces, chemicals which may result in skin irritation, dermatitis, and may affect the central nervous system via inhalation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 19, 2025
Abate by
Mar 19, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve:  (a) 3147 Century St, Colorado Springs, CO 80907: On or about November 19, 2024, and at times prior, the employer did not ensure that respirators were stored to protect them from damage, contamination, and dust. Respirators were observed hanging from shelving, with no protective coverings, near production chemicals in the formulation and extraction rooms.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 5 1 instance 8 exposed
Issued
Feb 19, 2025
Abate by
Mar 19, 2025
Penalty
Initial $6,620 · Current $3,972 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes were not provided within the work area for immediate emergency use:  (a) 3147 Century St, Colorado Springs, CO 80907: On or about November 19, 2024, and at times prior, the employer did not ensure that an eyewash station was available where employees were exposed to a corrosive chemical. Employees measure and dispense Bacti-Free Third Sink Sanitizer, a corrosive liquid, in the gummy room for cleaning throughout the facility. Eye exposure to the chemicals in use in the employer's workplace may result in serious eye damage including loss of vision.
Recent events (2)
  • — I (S) $3972
  • — Z (S) $6620

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347894859.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.