CHICAGO, IL —
OSHA Inspection: DUDEK & BOCK SPRING MANUFACTURING CO
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DUDEK & BOCK SPRING MANUFACTURING CO in 5100 ROOSEVELT ROAD, CHICAGO, IL 60644 (NAICS 332613). OSHA activity number 347898785.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DUDEK & BOCK SPRING MANUFACTURING CO
- Site address
- 5100 ROOSEVELT ROAD
- City
- CHICAGO
- State
- IL
- ZIP
- 60644
- Mailing
- 5100 ROOSEVELT ROAD, CHICAGO, IL 60644
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332613
- Employees
- 155
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D
- Issued
- Feb 5, 2025
- Abate by
- Feb 25, 2025
- Penalty
- Initial $14,895 · Current $14,895
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a) CNC Wire Forming Department - On or about November 8, 2024, employees were exposed to machine hazards associated with moving parts when clearing material from the PAVE CNC Machine #5. The employer failed to implement energy control application steps as the machine was not shut down or turn off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)((i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (1)
- — Z (S) $14895
More inspections at Dudek & Bock Spring Manufacturing CO
View Dudek & Bock Spring Manufacturing CO's full OSHA safety record →
More inspections in this industry (NAICS 332613)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347898785.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.