Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMTEC CORPORATION

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of AMTEC CORPORATION in 47600 180TH STREET, CLEAR LAKE, SD 57226 (NAICS 325920). OSHA activity number 347909038.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Amtec Corporation — free Get an email when a new federal OSHA severe-injury report for Amtec Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
AMTEC CORPORATION
Site address
47600 180TH STREET
City
CLEAR LAKE
State
SD
ZIP
57226
Mailing
47600 180TH STREET, CLEAR LAKE, SD 57226
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325920
Employees
175
Ownership type
A

10 citations on file for this inspection.

1910.119 F01

Other-than-serious Gravity 10 2 instances 2 exposed
Issued
May 6, 2025
Abate by
Jun 6, 2025
Penalty
Initial $16,550 · Current $13,240 Reduced
29 CFR  1910.119(f)(1): The employer did not develop and implement written operating procedures that provide clear instructions for safely conducting activities involved in each covered process:  a)AMTEC Corporation dba Tech Ord, a Division of AMTEC Corporation at 47600 180th Street, Clear Lake, SD 57226: On or about and at times prior to November 25, 2024, the employer did not ensure the Product Realization Operating Procedure Manufacture of PY-951 Document Number 710054 Revision N, provided clear instruction for air drying PY-951, allowing evaporation of methyl ethyl ketone,  prior to screening as described in Section 5.4.11.  Screening PY-951 with a higher or lower than ideal concentration of methyl ethyl ketone can increase risk of detonation. The operating procedure does not provide clear instructions for operators to identify an appropriate endpoint for air drying of PY-951.  This condition exposed employees to explosion hazards.  b)AMTEC Corporation dba Tech Ord, a Division of AMTEC Corporation at 47600 180th Street, Clear Lake, SD 57226: On or about and at times prior to November 25, 2024, the employer did not develop and implement the Machine Operating Procedure Sweco Vibratory Screener Document Number 600086-050  Revision F including clear instruction for operators addressing the upset condition of a blinded screen as described on page 3 of 20.  An employee suffered burns following detonation of PY-951 when addressing the upset condition of a blinded screen.  This condition exposed employees to explosion hazards.
Recent events (2)
  • — I (O) $13240
  • — Z (S) $16550

1910.119 F01 I G

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
May 6, 2025
Abate by
Jun 6, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.119(f)(1)(i)(G):The employer did not develop and implement written operating procedures that provide clear instructions for safely conducting activities involved in each covered process consistent with the process safety information and did not address the startup following a turnaround, or after an emergency shutdown:  a)AMTEC Corporation dba Tech Ord, a Division of AMTEC Corporation at 47600 180th Street, Clear Lake, SD 57226: On or about and at times prior to November 25, 2024, the employer did not provide in the Product Realization Operating Procedure Manufacture of PY-951 Document Number 710054 Revision N clear instructions for Start-Up Following an Emergency Shutdown for PY-951 transferred to velostat trays, as described in Steps 5.4.9 and 5.4.10, where screening is not initiated prior to the emergency shutdown.  This condition exposed employees to explosion hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D01 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
May 6, 2025
Abate by
Jun 6, 2025
Penalty
Initial $16,550 · Current $0 Reduced
29 CFR  1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment:   a)AMTEC Corporation dba Tech Ord, a Division of AMTEC Corporation, 47600 180th Street, Clear Lake, SD 57226: On or about and at times prior to November 25, 2024, the employer did not ensure employees screening pyrotechnic materials in Building 105 utilized aluminized overpant and jacket. This condition exposed employee to burn hazards in the event of a detonation or fire occurs during screening of pyrotechnic materials.
Recent events (2)
  • — I (S) $0
  • — Z (S) $16550

1910.132 E

Other-than-serious Gravity 10 1 instance 4 exposed
Issued
May 6, 2025
Abate by
Jun 6, 2025
Penalty
Initial $0 · Current $13,240
29 CFR  1910.132(e): Defective and damaged equipment. The employer did not ensure defective or damaged personal protective equipment was taken out of service and/or not used.  a)AMTEC Corporation dba Tech Ord, a Division of AMTEC Corporation, 47600 180th Street, Clear Lake, SD 57226: On or about and at times prior to November 25, 2024, the employer did not ensure defective or damaged aluminized overpant, jacket and hoods were taken out of service and/or not used. This condition exposed  employees to burn hazards in the event of a detonation or fire.
Recent events (2)
  • — I (O) $13240
  • — Z (S) $0

1910.133 A01

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
May 6, 2025
Abate by
Jun 6, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  a)AMTEC Corporation dba Tech Ord, a Division of AMTEC Corporation, 47600 180th Street, Clear Lake, SD 57226: On or about and at times prior to November 25, 2024, the employer did not ensure employees utilized appropriate face and eye protection when processing pyrotechnics in Building 105 to prevent employee exposure to burn hazards in the event of a detonation or fire.  This condition exposed employees to struck-by and burn  hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.138 A

Deleted Serious Gravity 10 2 instances 4 exposed
Issued
May 6, 2025
Abate by
Jun 6, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.138(a):The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes:  a)AMTEC Corporation dba Tech Ord, a Division of AMTEC Corporation, 47600 180th Street, Clear Lake, SD 57226: On or about and at times prior to November 25, 2024, the employer did not ensure employees utilized appropriate hand protection when processing pyrotechnics in Building 105.  This condition exposed employees to burn and explosion hazards.  b)AMTEC Corporation dba Tech Ord, a Division of AMTEC Corporation, 47600 180th Street, Clear Lake, SD 57226: On or about and at times prior to November 25, 2024, the employer did not ensure employees used appropriate and chemically compatible hand protection when working with 2-butanone (methyl ethyl ketone) and methylene chloride solvents in Building 105. The employer provided employee nitrile based gloves which offers poor chemical compatibility for 2-butanone and methylene chloride and is prone to breakthrough.  This condition exposed employees to skin sensitization, irritation and dermatitis.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Deleted Serious Gravity 1 1 instance 4 exposed
Issued
May 6, 2025
Abate by
Jun 6, 2025
Penalty
Initial $7,802 · Current $0 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a)AMTEC Corporation dba Tech Ord, a Division of AMTEC Corporation, 47600 180th Street, Clear Lake, SD 57226: On or about and at times prior to November 25, 2024, the employer did not ensure appropriate guarding was implemented on the Cincinnati Fan Model 500S on the west external wall of Building 105 to prevent employee exposure to pinch-point hazards created by movement between the blower wheel and the wheel housing. This condition exposed employees to pinch-point hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7802

1910.219 E03 I

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
May 6, 2025
Penalty
Initial $0 · Current $6,242
29 CFR  1910.219(e)(3)(i):Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o);  a)AMTEC Corporation dba Tech Ord, a Division of AMTEC Corporation, 47600 180th Street, Clear Lake, SD 57226: On or about and at times prior to November 25, 2024, the employer did not ensure employees operating the Mikro Samplemill (Serial Number 81J5186) were protected from ingoing nip points created by an unguarded vertical belt and pulley. This condition exposed employees to ingoing nip-point hazards.
Recent events (2)
  • — I (O) $6242
  • — Z (S) $0

1910.119 G03

Serious Gravity 5 4 instances 4 exposed
Issued
May 6, 2025
Abate by
Jun 6, 2025
Penalty
Initial $26,011 · Current $16,550 Reduced
29 CFR  1910.119(g)(3):Training documentation. The employer shall ascertain that each employee involved in operating a process has received and understood the training required by this paragraph. The employer shall prepare a record which contains the identity of the employee, the date of training, and the means used to verify that the employee understood the training:  a)AMTEC Corporation dba Tech Ord, a Division of AMTEC Corporation, 47600 180th Street, Clear Lake, SD 57226: On or about and at times prior to November 25, 2024, the employer did not ensure employees operating the Sweco Vibratory Screener  to process pyrotechnics materials had completed training on the Machine Operating Procedure Sweco Vibratory Screener Document Number 600086-050 Revision F by preparing a record which contained the identity of the employee, the date of training, and the means used to verify that the employee understood the training. This condition exposed employees to fire and explosion hazards.   b)AMTEC Corporation dba Tech Ord, a Division of AMTEC Corporation, 47600 180th Street, Clear Lake, SD 57226: On or about and at times prior to November 25, 2024, the employer did not ensure employees preparing PY-951 had completed training on the Product Realization Operating Procedure Manufacture of PY-951 Document Number 710054 Revision N  by preparing a record which contained the identity of the employee, the date of training, and the means used to verify that the employee understood the training. This condition exposed employees to fire and explosion hazards.   c)AMTEC Corporation dba Tech Ord, a Division of AMTEC Corporation, 47600 180th Street, Clear Lake, SD 57226: On or about and at times prior to November 25, 2024, the employer did not ensure employees preparing I-308 had completed training on the Product Realization Operating Procedure Manufacture of I-308 Document Number 7000206 Revision L by preparing a record which contained the identity of the employee, the date of training, and the means used to verify that the employee understood the training. This condition exposed employees to fire and explosion hazards.   d)AMTEC Corporation dba Tech Ord, a Division of AMTEC Corporation, 47600 180th Street, Clear Lake, SD 57226: On or about and at times prior to November 25, 2024, the employer did not ensure employees operating the Mikro Samplemill to process pyrotechnics materials had completed training on the Machine Operating Procedure Mikro Samplmill (Hammer Mill) Document Number 600092-050 Revision C by preparing a record which contained the identity of the employee, the date of training, and the means used to verify that the employee understood the training. This condition exposed employees to fire and explosion hazards.   AMTEC Corporation dba Tech Ord, a Division of AMTEC Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR  1910.119(g)(3), which was contained in OSHA inspection number 1627407, citation number 1, item number 5b and was affirmed as a final order on September 20, 2023, with respect to a workplace located at 47600 180th Street, Clear Lake, SD 57226.
Recent events (2)
  • — I (S) $16550
  • — Z (R) $26011

1910.134 C02 I

Deleted Other-than-serious 1 instance 2 exposed
Issued
May 6, 2025
Abate by
Jun 6, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.134(c)(2)(i):Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  a)AMTEC Corporation dba Tech Ord, a Division of AMTEC Corporation at 47600 180th Street, Clear Lake, SD 57226: On or about and at times prior to November 25, 2024, the employer did not ensure employees were provided with the information contained in Appendix D to 29 CFR 1910.134 that were allowed to voluntarily use respiratory protection.  This condition exposed employees to respiratory hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Amtec Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347909038.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.