HAZLETON, PA ·
OSHA Inspection: JOHNS MANVILLE CORP
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of JOHNS MANVILLE CORP in 600 JAYCEE DRIVE, HAZLETON, PA 18202 (NAICS 326150). OSHA activity number 347913220.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JOHNS MANVILLE CORP
- Site address
- 600 JAYCEE DRIVE
- City
- HAZLETON
- State
- PA
- ZIP
- 18202
- Mailing
- 600 JAYCEE DRIVE, HAZLETON, PA 18202
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326150
- Employees
- 80
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 17, 2025
- Abate by
- Jul 18, 2025
- Penalty
- Initial $16,550 · Current $0 Reduced
E200
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the recognized hazard of a dust collector located inside of the building that did not meet the requirements of NFPA 654 which created a fire hazard: a) Baler House- On or about December 4, 2024, employees working in the baler house area were exposed to flash fire and fire hazards from a dust collector integrated into a baler system that was not located outside of the building and protected in accordance with NFPA 654. Abatement certification and documentation required.
Recent events (2)
- · I (S) $0
- · Z (S) $16550
1910.22 A01
- Issued
- Apr 17, 2025
- Abate by
- May 1, 2025
- Penalty
- Initial $16,550 · Current $13,240 Reduced
E200
General-duty citation text
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition: a) Saw rooms- On or about December 4, 2024, employees working in and around the saw rooms were exposed to fire and fire hazards from improper housekeeping practices that allowed a buildup of combustible dust to accumulate on horizontal surfaces. b) Baler House- On or about December 4, 2024, employees working in the baler house area were exposed to flash fire and fire hazards from improper housekeeping practices that allowed a buildup of combustible dust to accumulate on horizontal surfaces. Abatement certification and documentation required.
Recent events (2)
- · I (S) $13240
- · Z (S) $16550
1910.22 A02
- Issued
- Apr 17, 2025
- Abate by
- May 1, 2025
- Penalty
- Initial $0 · Current $0
E200
General-duty citation text
29 CFR 1910.22(a)(2): The employer did not ensure that the floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition: a) Saw rooms- On or about December 4, 2024, employees working in and around the saw rooms were exposed to flash fire and fire hazards from improper housekeeping practices that allowed a buildup of combustible dust to accumulate on floor surfaces. b) Baler House- On or about December 4, 2024, employees working in the baler house area were exposed to flash fire and fire hazards from improper housekeeping practices that allowed a buildup of combustible dust to accumulate on floor surfaces. Abatement certification and documentation required.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.307 C03
- Issued
- Apr 17, 2025
- Abate by
- May 12, 2025
- Penalty
- Initial $16,550 · Current $16,550
E200
General-duty citation text
29 CFR 1910.307(c)(3): The equipment used in the hazardous(classified) location was not of the type and design that would protect from the hazards arising from the combustibility and flammability of vapors, liquids, gases, dusts, or other fibers involved: a) Johns Manville Corp- On or about December 4, 2024, employees were exposed to flash fire and fire hazards from the use of electrical equipment in a Class III environment that would not protect from the combustible dust hazard in the establishment. Abatement certification and documentation required.
Recent events (2)
- · I (O) $16550
- · Z (S) $16550
More inspections at Johns Manville Corp
View Johns Manville Corp's full OSHA safety record →
More inspections in this industry (NAICS 326150)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347913220.