Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COLUMBUS INDUSTRIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of COLUMBUS INDUSTRIES, INC. in 11545 STATE ROUTE 41, WEST UNION, OH 45693 (NAICS 333999). OSHA activity number 347917833.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Columbus Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Columbus Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
11545 STATE ROUTE 41
City
WEST UNION
State
OH
ZIP
45693
Mailing
11545 STATE ROUTE 41, WEST UNION, OH 45693
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333999
Employees
89
Ownership type
A

4 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 8 exposed
Issued
Mar 27, 2025
Abate by
May 1, 2025
Penalty
Initial $8,276 · Current $8,276
29 CFR  1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  a) On and before December 05, 2024, the employer did not have an energy control program that consisted of energy control procedures, employee training and periodic inspections to ensure that prior to performing servicing and maintenance such as cleaning the ovens employees were protected from the unexpected energizing, startup or release of stored energy that could cause injury.
Recent events (1)
  • — Z (S) $8276

1910.212 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 27, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR  1910.212(a)(1):Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.  a) On or before December 05, 2024, the employer did not ensure that the Powermatic Drill Press was guarded.
Recent events (1)
  • — Z (S) $4965

1910.253 B04 I

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 27, 2025
Penalty
Initial $8,276 · Current $8,276
29 CFR  1910.253(b)(4)(i): Oxygen cylinders shall not be stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near any other substance likely to cause or accelerate fire; or in an acetylene generator compartment.   a) On or about December 05, 2024, the employer did not ensure that acetylene and propane tanks were stored separately from the oxygen tanks in the welding area.
Recent events (1)
  • — Z (S) $8276

1910.253 B04 III

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 27, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.253(b)(4)(iii): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.  a) On or about December 05, 2024, the employer did not ensure that acetylene and propane tanks were stored separately at a minimum distance of 20 feet from the oxygen tanks in the welding area.
Recent events (1)
  • — Z (S) $0

View Columbus Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347917833.