Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: D&W FINE PACK, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of D&W FINE PACK, LLC in 1112 MADISON STREET, FORT CALHOUN, NE 68023 (NAICS 326112). OSHA activity number 347919490.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D&W Fine Pack, LLC — free Get an email when a new federal OSHA severe-injury report for D&W Fine Pack, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
D&W FINE PACK, LLC
Site address
1112 MADISON STREET
City
FORT CALHOUN
State
NE
ZIP
68023
Mailing
1112 MADISON STREET, FORT CALHOUN, NE 68023
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326112
Employees
90
Ownership type
A

4 citations on file for this inspection.

1910.147 D04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 10, 2025
Abate by
Apr 3, 2025
Penalty
Initial $16,550 · Current $13,240 Reduced
29 CFR  1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:   On or about December 4th, 2024, employees engaged in maintenance related activities located at 1112 Madison Street, Fort Calhoun, Nebraska 68023, were exposed to in running nip point and rotating parts hazards in that an employee was attempting to clear a jam on the running Trim 7 Press Grinder without isolating the energy sources for the machine.  He got his hand caught in the grinder, amputating multiple fingers on his right hand.
Recent events (2)
  • — I (S) $13240
  • — Z (S) $16550

1910.305 A02 X

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 10, 2025
Penalty
Initial $13,005 · Current $10,404 Reduced
29 CFR  1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.  On or about December 4th, 2024, employees engaged in maintenance related activities located at 1112 Madison Street, Fort Calhoun, Nebraska 68023, were exposed to electrocution and fire hazards in that two ends of 480V/30 AMP cable that was ran from a junction box to a motor located under trim press #7 was damaged and was being used during normal production.
Recent events (2)
  • — I (S) $10404
  • — Z (S) $13005

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 10, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(2)(iii):Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  On or about December 4th, 2024, employees engaged in maintenance related activities located at 1112 Madison Street, Fort Calhoun, Nebraska 68023, were exposed to electrical and fire hazards in that that two ends of 480V/30 AMP cable that was ran from a junction box to a motor located under trim press #7 was damaged and strain relief was not being provided to the cables.  The employer was using the cables during normal production.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 10, 2025
Abate by
Apr 3, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(2)(i):Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  On or about December 4th, 2024, employees engaged in maintenance related activities located at 1112 Madison Street, Fort Calhoun, Nebraska 68023, were exposed to electrocution and fire hazards in that employees were using  480V/30 AMP cord that was ran from a junction box to a motor located under trim press #7 was damaged and was being used during normal production.  The cord in question were not being inspected for defects on the cable.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View D&W Fine Pack, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347919490.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.