POPLAR BLUFF, MO —
OSHA Inspection: SAINT FRANCIS MEDICAL CLINIC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SAINT FRANCIS MEDICAL CLINIC in 225 PHYSICIANS PARK DRIVE, POPLAR BLUFF, MO 63901 (NAICS 621111). OSHA activity number 347921546.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAINT FRANCIS MEDICAL CLINIC
- Site address
- 225 PHYSICIANS PARK DRIVE
- City
- POPLAR BLUFF
- State
- MO
- ZIP
- 63901
- Mailing
- 225 PHYSICIAN PARK DRIVE, POPLAR BLUFF, MO 63901
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 621111
- Employees
- 200
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C06 I
- Issued
- Mar 21, 2025
- Abate by
- Apr 9, 2025
- Penalty
- Initial $9,457 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure the procedure and the requirement of this standard were followed: On or about December 5, 2024, and times prior to, the employer St. Francis Medical Clinic Poplar Bluff located at 221 Physician Park in Poplar Bluff, Missouri, had not conducted periodic inspections of their lockout/tagout hazardous energy control procedures at least annually to ensure procedures and the requirements of this standard were followed.
Recent events (2)
- — I (S) $0
- — Z (S) $9457
1910.147 C07 I
- Issued
- Mar 21, 2025
- Abate by
- Apr 9, 2025
- Penalty
- Initial $7,093 · Current $3,547 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The training program of the employer did not include all the training elements listed under items a-c of 29 CFR 1910.147(c)(7)(i): On or about December 5, 2024 and times prior to, employees of St. Francis Medical Clinic Poplar Bluff located at 221 Physician Park in Poplar Bluff, Missouri, perform equipment maintenance tasks, including but not limited to, motor replacement, electrical repairs, and servicing of facility systems. The employer did not ensure authorized and affected employees were trained with the knowledge and skills required to perform their job safely.
Recent events (2)
- — I (S) $3547
- — Z (S) $7093
1910.332 B01
- Issued
- Mar 21, 2025
- Abate by
- Apr 9, 2025
- Penalty
- Initial $16,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: On or about December 5, 2024 and times prior to, employees of St. Francis Medical Clinic Poplar Bluff located at 221 Physician Park in Poplar Bluff, Missouri, were troubleshooting and making electrical repairs to a light fixture. The employer did not ensure maintenance employees were provided with training on electrical safety-related work practices such as but not limited to, arc flash hazards, protective equipment for the hands, head and body to protect against electrical hazards while working on or near energized or potentially energized electrical parts. Employees were exposed to 277 volt electrical hazards while troubleshooting light ballasts and replacing bulbs.
Recent events (2)
- — I (S) $0
- — Z (S) $16550
1910.333 A01
- Issued
- Mar 21, 2025
- Abate by
- Apr 9, 2025
- Penalty
- Initial $16,550 · Current $8,275 Reduced
General-duty citation text
29 CFR 1910.333(a)(1):"Deenergized parts." Live parts to which an employee may be exposed were not deenergized before the employee works on or near them: On or about December 5, 2024, employees of St. Francis Medical Clinic Poplar Bluff located at 221 Physician Park in Poplar Bluff, Missouri, were making electrical repairs to a light fixture. The employer did not ensure the electrical energy source was deenergized before the work commenced. The employees working on the light fixture were exposed to electrical hazards of approximately 277 volts.
Recent events (2)
- — I (S) $8275
- — Z (S) $16550
More inspections in this industry (NAICS 621111)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347921546.