MISSOULA, MT —
OSHA Inspection: HARLOW'S BUS SALES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HARLOW'S BUS SALES in 8275 U.S. HIGHWAY 10 WEST BLDG 2, MISSOULA, MT 59808 (NAICS 811111). OSHA activity number 347925497.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HARLOW'S BUS SALES
- Site address
- 8275 U.S. HIGHWAY 10 WEST BLDG 2
- City
- MISSOULA
- State
- MT
- ZIP
- 59808
- Mailing
- 8275 U.S. HIGHWAY 10 WEST, MISSOULA, MT 59808
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 16
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Apr 2, 2025
- Penalty
- Initial $2,412 · Current $1,447 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. Fabrication Shop: On or about December 10, 2024, and at time prior, employees were exposed to caught in hazards from the rotating chuck of the 15' Floor Drill Press Model: J-2500 Serial No. 14092394 made by Jet while drilling holes into metal.
Recent events (2)
- — I (S) $1447.2
- — Z (S) $2412
1910.305 G01 IV A
- Issued
- Apr 2, 2025
- Penalty
- Initial $2,412 · Current $1,447 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. Bay 2: On or about December 10, 2024, and at times prior, employees were exposed to electric shock and fire hazards while using flexible extension cords to power a Mac Toolbox.