FALLON, NV —
OSHA Inspection: NAVSUP - FALLON
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NAVSUP - FALLON in 4755 PASTURE ROAD BLDG 25, FALLON, NV 89496 (NAICS 488190). OSHA activity number 347929770.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NAVSUP - FALLON
- Site address
- 4755 PASTURE ROAD BLDG 25
- City
- FALLON
- State
- NV
- ZIP
- 89496
- Mailing
- 4755 PASTURE ROAD, BLDG 25 ASD - FALLON, FALLON, NV 89496
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488190
- Employees
- 8
- Ownership type
- D
Citations
2 citations on file for this inspection.
1910.178 A04
- Issued
- Jan 6, 2025
- Abate by
- Jan 31, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly. BUILDING 25: On December 3, 2024 and at times prior thereto, the data plate on a Hyster Lift Truck, model H60FTM, serial no. L177G04800D, was not changed to reflect the capacity of the truck with the fork extensions at the facility. Use of a forklift with additions such as fork extensions can affect the capacity and stability of the truck. This condition potentially exposed employees to machine tipovers which can cause crushing injuries.
Recent events (1)
- — Z (S) $0
1910.303 G01
- Issued
- Jan 6, 2025
- Abate by
- Jan 16, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: Building 25: On December 3, 2024 and at times prior thereto, the working space around electrical equipment including a 480 volt panel and three switches was blocked by a piece of plywood and a large fan. Obstructing the electrical panels with large items can increase the amount of time it takes to access the panel in the event of an emergency. This condition potentially exposed employees to an electrical hazard.
Recent events (1)
- — Z (O) $0
More inspections at Navsup - Fallon
View Navsup - Fallon's full OSHA safety record →
More inspections in this industry (NAICS 488190)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347929770.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.