OSHA Inspection: 10 PLUS CONTRACTOR, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of 10 PLUS CONTRACTOR, LLC in 231 CLAY STREET, ENOLA, PA 17025 (NAICS 236118). OSHA activity number 347932717.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch 10 Plus Contractor, LLC — free Get an email when a new federal OSHA severe-injury report for 10 Plus Contractor, LLC is published. One employer, no account, unsubscribe in one click.
Site address
231 CLAY STREET
City
ENOLA
State
PA
ZIP
17025
Mailing
3583 LINCOLN HIGHWAY EAST PO BOX 292, KINZERS, PA 17535
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
236118
Employees
5
Ownership type
A

7 citations on file for this inspection.

1926.416 A01

Serious Gravity 5 1 instance 5 exposed
Issued
May 28, 2025
Abate by
Jun 24, 2025
Penalty
Initial $3,547 · Current $3,547
29 CFR 1926.416(a)(1):  The employer permitted employees to work in close proximity to energized, unguarded, and ungrounded electric power circuits that the employee could contact in the course of their work:  a.) 231 State Street, Enola, PA, Worksite, House Roof - On or about December 13, 2024, employees were accessing / egressing the roof of the structure to perform residential roofing activities via a Louisville metal extension ladder, and were in proximity to an energized electrical service line feeding into the structure that was not deenergized and grounded, or guarded by insulation or other means.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $3547

1926.21 B02

Serious Gravity 1 1 instance 5 exposed
Issued
May 28, 2025
Abate by
Jul 2, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.21(b)(2):  The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury:  a.) 231 State Street, Enola, PA, Worksite, House Roof - On or about December 13, 2024, employees were accessing / egressing the roof of the structure to perform residential roofing activities via a Louisville metal extension ladder while in proximity to an energized electrical service line feeding into the structure, and did not have electrical safety training to recognize hazards associated with overhead power lines.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 2 instances 5 exposed
Issued
May 28, 2025
Abate by
Jun 24, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR 1926.501(b)(13):  Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):   a.) 231 State Street, Enola, PA, Worksite, House Roof - On or about December 13, 2024, employees who were performing residential roofing work were exposed to a fall hazard of 11-feet and were not utilizing acceptable means or methods of fall protection.   b.) 231 State Street, Enola, PA, Worksite, House Roof - On or about December 13, 2024, employees who were performing residential roofing work were exposed to a fall hazard of 20-feet and were not utilizing acceptable means or methods of fall protection.   Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $4965

1926.503 A01

Serious Gravity 1 1 instance 5 exposed
Issued
May 28, 2025
Abate by
Jul 2, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1):  The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:   a.) 231 State Street, Enola, PA, Worksite, House Roof - On or about December 13, 2024, employees, who were performing residential roofing activities, were exposed to fall hazard hazards, and did not have fall protection training.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 5 exposed
Issued
May 28, 2025
Abate by
Jun 24, 2025
Penalty
Initial $2,837 · Current $2,837
29 CFR 1926.1053(b)(1):  Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a.) 231 State Street, Enola, PA, Worksite, House Roof - On or about December 13, 2024, employees engaged in roofing activities were exposed to a fall of 11-feet to grade while utilizing a Louisville metal extension ladder that was extended less than 1-foot above the roofline and was not otherwise secured.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $2837

1926.1053 B12

Serious Gravity 5 1 instance 5 exposed
Issued
May 28, 2025
Abate by
Jun 24, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(12):  Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive siderails:  a.) 231 State Street, Enola, PA, Worksite, House Roof - On or about December 13, 2024, employees were accessing the roof of the structure to perform residential roofing activities via a Louisville metal extension ladder, and were in proximity to an energized electrical service line feeding into the structure.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1926.1060 A

Serious Gravity 1 1 instance 5 exposed
Issued
May 28, 2025
Abate by
Jul 2, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a):  The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways:  a.) 231 State Street, Enola, PA, Worksite, House Roof - On or about December 13, 2024, employees were accessing / egressing the roof of the structure to perform residential roofing activities via a metal extension ladder, and did not have ladder safety training.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.