FALLSINGTON, PA —
OSHA Inspection: GEMINI PLASTICS INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GEMINI PLASTICS INCORPORATED in 7 HEADLEY PLACE, FALLSINGTON, PA 19054 (NAICS 326199). OSHA activity number 347933400.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GEMINI PLASTICS INCORPORATED
- Site address
- 7 HEADLEY PLACE
- City
- FALLSINGTON
- State
- PA
- ZIP
- 19054
- Mailing
- 7 HEADLEY PLACE, FALLSINGTON, PA 19054
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 15
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Mar 12, 2025
- Penalty
- Initial $4,729 · Current $2,365 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) 7 Headley Place Fallsington, PA 19054- On or about December 13, 2024, employees were exposed to caught in hazards in that the chuck on a lathe was not guarded.
Recent events (2)
- — I (S) $2365
- — Z (S) $4729
1910.147 C06 II
- Issued
- Mar 12, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The certification did not identify the machine or equipment on which the energy control procedure was being utilized: a) 7 Headley Place Fallsington, PA 19054- On or about December 13, 2024, the employer did not identify the machine or equipment on which the energy control procedure was being utilized on the periodic inspection certification.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Gemini Plastics Incorporated
View Gemini Plastics Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347933400.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.