OSHA Inspection: TOP NOTCH HOME REMODELING LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TOP NOTCH HOME REMODELING LLC in 2504 41ST NW, WASHINGTON, DC 20007 (NAICS 238130). OSHA activity number 347938367.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch TOP Notch Home Remodeling LLC — free Get an email when a new federal OSHA severe-injury report for TOP Notch Home Remodeling LLC is published. One employer, no account, unsubscribe in one click.
Site address
2504 41ST NW
City
WASHINGTON
State
DC
ZIP
20007
Mailing
10441 GOLDENROD DRIVE, BRISTOW, VA 20136
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

7 citations on file for this inspection.

1926.404 B01 II

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Mar 4, 2025
Abate by
Mar 12, 2025
Penalty
Initial $2,170 · Current $1,500 Reduced
29 CFR  1926.404(b)(1)(ii):On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection.  a) On or about December 12, 2024, at a worksite located at 2504 41st NW Street NW, third floor, employees were operating electrical equipment such as saws and compressors that were not protected by a ground-fault circuit interrupter, exposing them to a shock hazard.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $2170

1926.405 B02

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Mar 4, 2025
Abate by
Mar 12, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.405(b)(2):In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:  a) On or about December 12, 2024, at a worksite located at 2504 41st NW Street NW, third floor, employees were operating electrical equipment such as saws and compressors that were plugged into outlets that were missing faceplates exposing them to a shock hazard.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 4, 2025
Abate by
Mar 12, 2025
Penalty
Initial $4,220 · Current $4,000 Reduced
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) On or about December 12, 2024, at a worksite located at 2504 41st NW Street NW, third floor, employees, while receiving material through a floor opening, did not have fall protection in place to prevent them from falling an estimated 20 feet to the lower wooden decked floors.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $4220

1926.1053 B01

Other-than-serious Gravity 10 1 instance 4 exposed
Issued
Mar 4, 2025
Abate by
Mar 12, 2025
Penalty
Initial $3,798 · Current $2,500 Reduced
29 CFR  1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a)  On or about December 12, 2024; at a worksite located at 2504 41st NW Street NW, westside back of site, employees engaged in framing activities were using an extension ladder that was extended 2 feet above the landing exposing them to exposing to an estimated 20-foot fall while accessing the work area or the ladder.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $2500
  • — Z (S) $3798

1926.1053 B08

Other-than-serious Gravity 10 1 instance 4 exposed
Issued
Mar 4, 2025
Abate by
Mar 12, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder.  a)  On or about December 12, 2024, at a worksite located at 2504 41st NW Street NW, westside back of the site, employees engaged in framing activities were using an extension ladder that was not secured, exposing them to displacement while using it to access work area; exposing to an estimated 20-foot fall.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.1053 B15

Other-than-serious Gravity 10 1 instance 4 exposed
Issued
Mar 4, 2025
Abate by
Mar 12, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(15):Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use:  a)  On or about December 12, 2024, at a worksite located at 2504 41st NW Street NW, westside back of site, employees engaged in framing activities were using an extension ladder that was not inspected by a competent person that can recognize the hazards associated with the ladders such as placement of the ladder, securing, damaged assessment and how to abate those conditions. Those conditions existed at the location and exposed the employees to an estimated fall of 20 feet while using the ladder to access the work area.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.1053 B16

Other-than-serious Gravity 10 1 instance 4 exposed
Issued
Mar 4, 2025
Abate by
Mar 12, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(16): Portable ladder(s) with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components  a) On or about December 12, 2024; at a worksite located at 2504 41st NW Street NW, westside back of site, employees engaged in framing activities were using an extension ladder in the rungs were damaged exposing to an estimated 20-foot fall while accessing the work area or the ladder.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.