Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JACK KENNEDY METAL PRODUCTS & BUILDINGS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JACK KENNEDY METAL PRODUCTS & BUILDINGS, INC. in 1434 N, 960 E TAYLORVILLE RD, TAYLORVILLE, IL 62568 (NAICS 423840). OSHA activity number 347938573.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jack Kennedy Metal Products & Buildings, INC. — free Get an email when a new federal OSHA severe-injury report for Jack Kennedy Metal Products & Buildings, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1434 N, 960 E TAYLORVILLE RD
City
TAYLORVILLE
State
IL
ZIP
62568
Mailing
PO BOX 138, TAYLORVILLE, IL 62568
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423840
Employees
29
Ownership type
A

5 citations on file for this inspection.

1910.151 C

Other-than-serious 1 instance 10 exposed
Issued
Apr 4, 2025
Abate by
Apr 21, 2025
Penalty
Initial $0 · Current $0

Hazardous substances 2310

29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:   On or about December 17, 2024, employees were exposed to chemical hazards when eyewash stations were blocked by materials near the Powered Industrial Truck battery charging location.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 A04

Other-than-serious 2 instances 29 exposed
Issued
Apr 4, 2025
Abate by
May 12, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(4): Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:  On or about December 17, 2024, employees were exposed to crushing hazards due to forks being modified by drilling 1 inch holes in the forks without manufacturers approval.  (a) Caterpillar V80D S/N 40X01625  (b) Caterpillar M40D S/N 23N898
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 A06

Other-than-serious 5 instances 29 exposed
Issued
Apr 4, 2025
Abate by
May 12, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were maintained in a legible condition:  On or about December 17, 2024, employees were exposed to crushing hazards associated with improperly handled loads when multiple fork trucks had data placards that were illegible.  (a) Hyster Model ZC-20 Asset 910-0002 (b) Hyster Diesel Asset 910-0011 (c) Clark Clipper Asset 910-0013 (d) Caterpillar Diesel Asset 910-0052 (e) Hyster Challenger 80 Asset 910-0036
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 Q01

Other-than-serious 1 instance 29 exposed
Issued
Apr 4, 2025
Abate by
May 12, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:  On or about December 17, 2024, employees were exposed to electrical hazards due to exposed electrical wiring on the battery charging cable of a Powered Industrial Truck.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 4 exposed
Issued
Apr 4, 2025
Penalty
Initial $930 · Current $465 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  On or about December 17, 2024, employees were exposed to electrical hazards when multiple Powered Industrial Trucks were blocking access to electrical panels.
Recent events (2)
  • — I (O) $465
  • — Z (O) $930

View Jack Kennedy Metal Products & Buildings, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347938573.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.