Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STONE MOUNTAIN ACCESS SYSTEMS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of STONE MOUNTAIN ACCESS SYSTEMS in 4500 SAN PABLO ROAD, JACKSONVILLE, FL 32224 (NAICS 532490). OSHA activity number 347940470.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stone Mountain Access Systems — free Get an email when a new federal OSHA severe-injury report for Stone Mountain Access Systems is published. One employer, no account, unsubscribe in one click.
Site address
4500 SAN PABLO ROAD
City
JACKSONVILLE
State
FL
ZIP
32224
Mailing
4053 MAY STREET, HILLSIDE, IL 60162
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
532490
Employees
150
Ownership type
A

3 citations on file for this inspection.

1926.451 A03

Deleted Serious Gravity 10 3 instances 2 exposed
Issued
Jun 13, 2025
Abate by
Jul 3, 2025
Penalty
Initial $14,895 · Current $0 Reduced
29 CFR  1926.451(a)(3):Each suspension rope, including connecting hardware, used on non-adjustable suspension scaffolds was not capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope:  a. a. Located at 4500 San Pablo Road, Jacksonville, Florida, 32224 on or about December 12, 2024 employees were exposed to fall hazards while working from a swing stage scaffold.
Recent events (2)
  • — I (S) $0
  • — Z (S) $14895

1926.451 D03 I

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Jun 13, 2025
Penalty
Initial $0 · Current $8,000
29 CFR  1926.451(d)(3)(i):Before the scaffold was used, direct connections were not evaluated by a competent person to confirm, based on the evaluation, that the supporting surfaces are capable of supporting the loads to be imposed:   a. Located at 4500 San Pablo Road, Jacksonville, Florida, 32224 on or about December 12, 2024 employees were exposed to fall hazards while working from a swing stage scaffold.
Recent events (2)
  • — I (O) $8000
  • — Z (S) $0

1926.451 G01 I

Other-than-serious Gravity 10 3 instances 2 exposed
Issued
Jun 13, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.451(g)(1)(i):Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:  a. Located at 4500 San Pablo Road, Jacksonville, Florida, 32224 on or about December 12, 2024 employees were exposed to fall hazards while working from a swing stage scaffold.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347940470.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.