EDWARDSVILLE, IL —
OSHA Inspection: CLUB CAR WASH OPERATING, LLC DBA CLUB CAR WASH - EDWARDSVILLE
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CLUB CAR WASH OPERATING, LLC DBA CLUB CAR WASH - EDWARDSVILLE in 6627 GOVERNORS PARKWAY, EDWARDSVILLE, IL 62025 (NAICS 811192). OSHA activity number 347940652.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 6627 GOVERNORS PARKWAY
- City
- EDWARDSVILLE
- State
- IL
- ZIP
- 62025
- Mailing
- 1591 EAST PRATHERSVILLE ROAD, COLUMBIA, MO 65202
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811192
- Employees
- 14
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 I
- Issued
- Apr 15, 2025
- Abate by
- May 30, 2025
- Penalty
- Initial $11,823 · Current $6,503 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about December 8, 2024, the employer did not develop, document or utilize lockout/tagout procedures for the control of potentially hazardous energy when employees were engaged with servicing the Prep Station Pressure Gun machinery located in the equipment room.
Recent events (2)
- — I (S) $6503
- — Z (S) $11823
1910.147 D
- Issued
- Apr 15, 2025
- Abate by
- May 30, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): Instance 1 On or about December 8, 2024, the prep station pressure gun machinery in the equipment room was not locked out during adjustment and trimming of the frayed motor belt. Instance 2 On or about December 8, 2024, the prep station pressure gun machinery in the equipment room was not locked out during servicing work/troubleshooting work. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Apr 15, 2025
- Penalty
- Initial $11,823 · Current $6,503 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about December 8, 2024, the four pulleys installed on the two prep station pressure gun motor and pump assemblies, located in the equipment room next to the entrance door were not guarded during operation.
Recent events (2)
- — I (S) $6503
- — Z (S) $11823
1910.219 E01 I
- Issued
- Apr 15, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): On or about December 8, 2024, the horizontal drive belts installed on the two prep station pressure gun motor and pump assemblies, located in the equipment room next to the entrance door were not guarded during operation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 811192)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347940652.