SAN ANTONIO, TX —
OSHA Inspection: TEXSTAR ENTERPRISES, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TEXSTAR ENTERPRISES, LLC in 8615 POTRANCO ROAD, SAN ANTONIO, TX 78251 (NAICS 237130). OSHA activity number 347941148.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TEXSTAR ENTERPRISES, LLC
- Site address
- 8615 POTRANCO ROAD
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78251
- Mailing
- 17090 JORDAN RD., SELMA, TX 78154
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237130
- Employees
- 230
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.651 C02
- Issued
- Feb 13, 2025
- Penalty
- Initial $10,641 · Current $6,385 Reduced
S777
General-duty citation text
29 CFR 1926.651(c)(2):A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: On or about December 17, 2024, employees working to install fiber optic cable inside an excavation whose depth was greater than 4 feet did not have a safe means of egress within 25 feet where they were working.
Recent events (2)
- — I (O) $6385
- — Z (S) $10641
1926.652 A01 II
- Issued
- Feb 13, 2025
- Penalty
- Initial $10,641 · Current $0 Reduced
S777
General-duty citation text
29 CFR 1926.652(a)(1)(ii):29 CFR 1926.652(a)(1)(ii): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph 29 CFR 1926.652(b) or 29 CFR 1926.652(c) of this section except when: excavations are less than 5 feet (1.52 m) in depth and examination of the ground by a competent person provides no indication of a potential cave-in.: On or about December 17, 2024, employees working to install fiber optic cable inside an excavation area that was five feet in depth were not protected from cave-ins.
Recent events (2)
- — I (S) $0
- — Z (S) $10641
More inspections at Texstar Enterprises, LLC
View Texstar Enterprises, LLC's full OSHA safety record →
More inspections in this industry (NAICS 237130)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347941148.