HIGHLAND PARK, IL —
OSHA Inspection: VEGA GUTTERS AND CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VEGA GUTTERS AND CONSTRUCTION INC. in 2579 SHERIDAN ROAD, HIGHLAND PARK, IL 60035 (NAICS 238160). OSHA activity number 347941692.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VEGA GUTTERS AND CONSTRUCTION INC.
- Site address
- 2579 SHERIDAN ROAD
- City
- HIGHLAND PARK
- State
- IL
- ZIP
- 60035
- Mailing
- 5716 W GRAND AVE., CHICAGO, IL 60639
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Apr 25, 2025
- Penalty
- Initial $4,965 · Current $3,200 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) On December 18, 2024, at the above addressed jobsite, employees performing roofing work on residential home, approximately 9 feet above the ground below on the north side of the home, were not secured to a personal fall arrest systems or other means of fall protection, thereby exposing the employees to fall hazards. b) On December 10, 2024, at the above addressed jobsite, employees performing roofing work on residential home, approximately 22 feet above the ground below on the south side of the home, were not secured to a personal fall arrest systems or other means of fall protection, thereby exposing the employees to fall hazards. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $3200
- — Z (S) $4965
1926.1053 B01
- Issued
- Apr 25, 2025
- Penalty
- Initial $2,837 · Current $1,800 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On December 18, 2024, at the above addressed jobsite, the two portable ladders used by employees to access and egress the roof over on the north side, measuring approximately 9 feet from ground to the eve, were not extended to have the side rails extend at least three (3) feet above the upper landing. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $1800
- — Z (S) $2837
1926.1053 B16
- Issued
- Apr 25, 2025
- Penalty
- Initial $2,837 · Current $1,800 Reduced
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladder(s) with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately. a) On December 18, 2024, at the above addressed jobsite, the portable ladder near the northwest corner of the roof was used by employees to access and egress the roof over on the north side, measuring approximately 9 feet from ground to the eve, with defects to the side rail and foot on the west most rail. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $1800
- — Z (S) $2837
More inspections at Vega Gutters and Construction INC.
View Vega Gutters and Construction INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347941692.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.