Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FRANMAR, INC. DBA FRANMAR CHEMICAL, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FRANMAR, INC. DBA FRANMAR CHEMICAL, INC. in 10282 E 1400 NORTH RD, BLOOMINGTON, IL 61705 (NAICS 325199). OSHA activity number 347942534.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Franmar, INC. DBA Franmar Chemical, INC. — free Get an email when a new federal OSHA severe-injury report for Franmar, INC. DBA Franmar Chemical, INC. is published. One employer, no account, unsubscribe in one click.
Site address
10282 E 1400 NORTH RD
City
BLOOMINGTON
State
IL
ZIP
61705
Mailing
10282 E 1400 NORTH RD, BLOOMINGTON, IL 61705
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325199
Employees
12
Ownership type
A

10 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 8, 2025
Abate by
Apr 23, 2025
Penalty
Initial $9,931 · Current $1,500 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level was protected from falling by a guardrail system, safety net system, travel restraint system or personal fall arrest system:  On or about December 18, 2024, employees working in Building 2 were exposed to a fall hazard of approximately 6 feet while mixing chemicals from a platform because a suitable fall protection system was not used.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $9931

1910.28 B11 II

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 8, 2025
Abate by
Apr 23, 2025
Penalty
Initial $4,965 · Current $1,500 Reduced
29 CFR 1910.28(b)(11)(ii):  The employer did not ensure that each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as described in 29 CFR 1910.28 Table D-2-Stairway Handrail Requirements:  On or about December 18, 2024, employees working in Building 2 were exposed to a fall hazard up to 6 feet while using the stairs to access the platform to mix chemicals because the stair rail system was missing a midrail.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $4965

1910.37 B02

Serious Gravity 1 2 instances 4 exposed
Issued
Apr 8, 2025
Abate by
Apr 23, 2025
Penalty
Initial $4,965 · Current $2,500 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  On or about December 18, 2024, employees were exposed to potential injuries from fire or other emergencies because:  a. the emergency exit located on the east wall in Building 2 was not marked with an exit sign.  b. the emergency exit located on the west wall in Building 2 was not marked with an exit sign.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4965

1910.38 B

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 8, 2025
Abate by
Apr 23, 2025
Penalty
Initial $4,965 · Current $2,500 Reduced
29 CFR 1910.38(b):  An emergency action plan was not in writing, kept in the workplace, and available to employees for review:  On or about December 18, 2024, employees were exposed to potential injuries from fire or other emergencies because the employer had not developed and implemented an emergency action plan.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4965

1910.39 B

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 8, 2025
Abate by
Apr 23, 2025
Penalty
Initial $4,965 · Current $2,500 Reduced
29 CFR 1910.39(b):  A fire prevention plan was not in writing, kept in the workplace, and be made available to employees for review:  On or about December 18, 2024, employees were exposed to potential injuries from fire or other emergencies because the employer had not developed and implemented a fire prevention plan.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4965

1910.101 B

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 8, 2025
Abate by
Apr 23, 2025
Penalty
Initial $4,965 · Current $1,500 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  On or about December 18, 2024, employees were exposed to struck by hazards because the compressed gas cylinders were not secured to prevent from being knocked over or damaged.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $4965

1910.157 C04

Other-than-serious Gravity 1 1 instance 6 exposed
Issued
Apr 8, 2025
Abate by
Apr 23, 2025
Penalty
Initial $4,965 · Current $0 Reduced
29 CFR 1910.157(c)(4):  Portable fire extinguishers were not kept in their designated places at all times except during use:   On or about December 18, 2024, employees working in Building 1 were exposed to potential injuries from fire or other emergencies because the fire extinguisher was missing from its designated place by the north exit door.
Recent events (2)
  • — I (O) $0
  • — Z (S) $4965

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 8, 2025
Abate by
Apr 23, 2025
Penalty
Initial $6,620 · Current $1,500 Reduced
29 CFR 1910.303(b)(2):  Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  On or about December 18, 2024, employees working in Building 2 were exposed to electrical hazards while using the electrical equipment for mixing chemicals because the four-way electrical box servicing the equipment was taped to the railing and not a permanent installation.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $6620

1910.305 A02 X

Other-than-serious Gravity 1 1 instance 4 exposed
Issued
Apr 8, 2025
Abate by
Apr 23, 2025
Penalty
Initial $4,965 · Current $0 Reduced
29 CFR 1910.305(a)(2)(x):  Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:  On or about December 18, 2024, employees working in Building 1 were exposed to electrical shock hazards because an electrical cord was run under an exit door to an exterior holiday wreath.
Recent events (2)
  • — I (O) $0
  • — Z (S) $4965

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 8, 2025
Abate by
Apr 23, 2025
Penalty
Initial $4,965 · Current $1,500 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  On or about December 18, 2024, an employee working in Building 1 was exposed to electrical hazards due to the lack of strain relief on the 220-volt cord supplying power to the air compressor.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $4965

View Franmar, INC. DBA Franmar Chemical, INC.'s full OSHA safety record →