HAMILTON, OH —
OSHA Inspection: DELFINO AGUILAR LOPEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DELFINO AGUILAR LOPEZ in 120 RANDOM DR, HAMILTON, OH 45013 (NAICS 238160). OSHA activity number 347949075.
Where did this inspection happen?
- Establishment
- DELFINO AGUILAR LOPEZ
- Site address
- 120 RANDOM DR
- City
- HAMILTON
- State
- OH
- ZIP
- 45013
- Mailing
- 1385 SPRING PARK WALK, CINCINNATI, OH 45215
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.20 B02
- Issued
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
29 CFR 1926.20(b)(2): Accident prevention responsibilities. Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers. a) On or about December 23, 2024, the employer did not conduct adequate inspections of the job site. As a result, employees were exposed to fall heights greater than 19 feet in that conventional fall protection was not being worn while performing roofing work and the ladder being used as access/egress was not extended 3 ft above the access point on the roof.
Recent events (1)
- — Z (S) $4965
1926.501 B13
- Issued
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. a) On or before December 23, 2024, the employer failed to ensure that employees performing roofing on a residential home were utilizing a fall protection system. As a result, employees were exposed to fall heights greater than 19 ft.
Recent events (1)
- — Z (S) $4965
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
29 CFR 1926.503(a)(1):The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards. a) On or about December 23, 2024, the employer failed to ensure that each employee exposed to a fall hazard was trained on the hazards of falling and the procedures to minimize the hazards in the work area. As a result, employees were exposed to fall hazards greater than 19 feet while performing residential roofing work.
Recent events (1)
- — Z (S) $4965
1926.1053 B01
- Issued
- Penalty
- Initial $4256.00 · Current $4256.00
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a) On or about December 23, 2024, the employer did not ensure that employees exposed to a fall hazard were protected in that the portable ladder used for accessing the roof only extended 1 ft above the upper landing surface.
Recent events (1)
- — Z (S) $4256
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in OH
WELLINGTON, OH—2026-07-16
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15
KENWORTH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347949075.