OSHA Inspection: BUSH BROTHERS & COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BUSH BROTHERS & COMPANY in 600 S BUSH BROTHERS DR., AUGUSTA, WI 54722 (NAICS 311421). OSHA activity number 347952905.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bush Brothers & Company — free Get an email when a new federal OSHA severe-injury report for Bush Brothers & Company is published. One employer, no account, unsubscribe in one click.
Site address
600 S BUSH BROTHERS DR.
City
AUGUSTA
State
WI
ZIP
54722
Mailing
600 S BUSH BROTHERS DR., AUGUSTA, WI 54722
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311421
Employees
165
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 2 instances 9 exposed
Issued
Apr 18, 2025
Abate by
May 2, 2025
Penalty
Initial $8,842 · Current $6,189 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Hyrdo cooker area; On or about December 27, 2024, the end section for the Stork Hydromatic can conveyor, near the infeed, was not guarded.  (b) Hydro cooker area; On or about December 27, 2024, the ceiling sections of the tunnels for the Stork Hydromatic can conveyor were unguarded.
Recent events (2)
  • — I (S) $6189.4
  • — Z (S) $8842

1910.219 C04 I

Serious Gravity 5 2 instances 6 exposed
Issued
Apr 18, 2025
Abate by
May 2, 2025
Penalty
Initial $8,842 · Current $6,189 Reduced
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:  (a) Soak area; On or about December 27, 2024, the shaft ends for the water separator conveyor in the bean hopper had split collars that were not guarded.  (b) Seamer process; On or about December 27, 2024, a shaft end for the seamer process machine conveyor had a collar with projecting set screw that was not guarded.
Recent events (2)
  • — I (S) $6189.4
  • — Z (S) $8842

1910.219 C04 II

Serious Gravity 5 1 instance 6 exposed
Issued
Apr 18, 2025
Abate by
May 2, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered:  (a) Soak area; On or about December 27, 2024, the bean hopper conveyor shaft with an unused keyway was not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Bush Brothers & Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347952905.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.