Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AVIENT CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AVIENT CORPORATION in 80 N. WEST ST., NORWALK, OH 44857 (NAICS 325211). OSHA activity number 347953002.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Avient Corporation — free Get an email when a new federal OSHA severe-injury report for Avient Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
AVIENT CORPORATION
Site address
80 N. WEST ST.
City
NORWALK
State
OH
ZIP
44857
Mailing
80 N. WEST ST., NORWALK, OH 44857
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
Employees
60
Ownership type
A

1 citation on file for this inspection.

1910.212 A01

Serious Gravity 10 2 instances 24 exposed
Issued
Feb 18, 2025
Abate by
Mar 3, 2025
Penalty
Initial $16,550 · Current $16,550
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a. On or about December 19, 2024, the employer did not ensure that the rotating screw auger, located within the throat hopper at the T2 Line Extrusion, was guarded.  Employees who purged the extrusion line by adding resin to throat hopper were exposed to caught-in hazards and amputation injury.   b. On or about December 19, 2024, the employer did not ensure that the rotating screw auger associated with the "side feeder," which feeds the throat hopper at the T2 Line Extrusion, was guarded.  Employees who purged the extrusion line by adding resin to the throat hopper were exposed to caught-in hazards and amputation injury.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (1)
  • — Z (S) $16550

View Avient Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347953002.