DALLAS, TX —
OSHA Inspection: COMMUNITY WASTE DISPOSAL, L.P.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COMMUNITY WASTE DISPOSAL, L.P. in 2010 CALIFORNIA CROSSING, DALLAS, TX 75220 (NAICS 562219). OSHA activity number 347962102.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COMMUNITY WASTE DISPOSAL, L.P.
- Site address
- 2010 CALIFORNIA CROSSING
- City
- DALLAS
- State
- TX
- ZIP
- 75220
- Mailing
- 2010 CALIFORNIA CROSSING, DALLAS, TX 75220
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562219
- Employees
- 462
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.178 L01 II
- Issued
- Jun 26, 2025
- Abate by
- Jul 23, 2025
- Penalty
- Initial $9,457 · Current $5,191 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck: (a) On or about January 6, 2025, employees operating industrial trucks were not provided with adequate forklift training.
Recent events (2)
- — I (O) $5191
- — Z (S) $9457
1910.178 L06
- Issued
- Jun 26, 2025
- Abate by
- Jul 23, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6):The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l): (a) On or about January 6, 2025, the employer did not ensure certification of forklift training was provided when operating Powered Industrial Trucks, throughout the area.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.178 P01
- Issued
- Jun 26, 2025
- Abate by
- Jul 23, 2025
- Penalty
- Initial $14,187 · Current $5,190 Reduced
General-duty citation text
29 CFR 1910.178(p)(1):Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): (a) On or about January 6, 2025, employees were operating a powered industrial truck and the horn was inoperable.
Recent events (2)
- — I (O) $5190
- — Z (S) $14187
1910.334 A02 I
- Issued
- Jun 26, 2025
- Penalty
- Initial $16,550 · Current $5,190 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i):Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): (a) On or about January 6, 2025, employees used an extension cord that was spliced and connected to a portable heater.
Recent events (2)
- — I (O) $5190
- — Z (S) $16550
1910.157 C01
- Issued
- Jun 26, 2025
- Penalty
- Initial $1,328 · Current $5,190
General-duty citation text
29 CFR 1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: On or about January 6, 2025, and times prior thereto, the employer did not have fire extinguishers readily available for emergencies: a. At the south end, near the back door, at least one (1) fire extinguisher was blocked with two (2) large toolboxes. b. At the Northeast side of the building, at least one (1) fire extinguisher was blocked with a Miller welding machine. c. At the Northeast side of the building, at least one (1) fire extinguisher was blocked by materials and a large toolbox. d. In the Welding area, at least three (3) fire extinguishers were on the ground and not mounted to the wall.
Recent events (2)
- — I (O) $5190
- — Z (O) $1328
More inspections in this industry (NAICS 562219)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347962102.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.