Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: ESSITY PROFESSIONAL HYGIENE NORTH AMERICA LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ESSITY PROFESSIONAL HYGIENE NORTH AMERICA LLC in 984 WINCHESTER ROAD, NEENAH, WI 54956 (NAICS 322299). OSHA activity number 347976169.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Essity Professional Hygiene North America LLC for free Get an email when a new federal OSHA severe-injury report for Essity Professional Hygiene North America LLC is published. One employer, no account, unsubscribe in one click.
Site address
984 WINCHESTER ROAD
City
NEENAH
State
WI
ZIP
54956
Mailing
984 WINCHESTER ROAD, NEENAH, WI 54956
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322299
Employees
55
Ownership type
Private (A)

1 citation on file for this inspection.

1910.334 A02 II

Deleted Other-than-serious 1 instance 10 exposed
Issued
Jan 24, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): If there is a defect or evidence of damage that might expose an employee to injury, the defective or damaged item shall be removed from service, and no employee may use it until repairs and tests necessary to render the equipment safe have been made.  On or about January 22, 2025, at the facility located at 984 Winchester Road, Neenah, Wisconsin; the charging cord that was plugged into the Core Chunk Mover (Kalmar Ac, Model No: WS30, Serial No.: WS3031331001) was not removed from service due to the defect of cut insulation, exposing employees to potential electrical shock and fire hazards.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Essity Professional Hygiene North America LLC's full OSHA safety record →