OSHA Inspection: HANKIN TIMBERS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HANKIN TIMBERS LLC in 228 MURFF DRIVE, GRENADA, MS 38901 (NAICS 321113). OSHA activity number 347980955.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hankin Timbers LLC — free Get an email when a new federal OSHA severe-injury report for Hankin Timbers LLC is published. One employer, no account, unsubscribe in one click.
Establishment
HANKIN TIMBERS LLC
Site address
228 MURFF DRIVE
City
GRENADA
State
MS
ZIP
38901
Mailing
PO BOX 1397, GRENADA, MS 38902
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
52
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 11, 2025
Abate by
Apr 29, 2025
Penalty
Initial $6,384 · Current $3,830 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.   (a) Sawmill-On or about January 15, 2025, the shaft and coupling for the conveyor at the Debarker was not guarded, exposing employees to moving parts.
Recent events (2)
  • — I (S) $3830.4
  • — Z (S) $6384

1910.242 B

Serious Gravity 1 1 instance 10 exposed
Issued
Apr 11, 2025
Penalty
Initial $6,384 · Current $3,830 Reduced
29 CFR  1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  (a) Throughout the facility - On or about January 15,2025 the employees were using compressed air set at 35-40 p.s.i. to clean equipment and employee's clothes, exposing employees to embolism hazards.
Recent events (2)
  • — I (S) $3830.4
  • — Z (S) $6384

1910.157 C01

Other-than-serious 1 instance 1 exposed
Issued
Apr 11, 2025
Abate by
Apr 29, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  (a) Throughout the facility - On or about January 15, 2025, the employer had fire extinguishers on the floor.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347980955.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.