CHELTENHAM, MD —
OSHA Inspection: DAYTON GROUP, INC
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of DAYTON GROUP, INC in 9000 COMMO ROAD BUILDING 101, CHELTENHAM, MD 20588 (NAICS 561210). OSHA activity number 347999260.
Where did this inspection happen?
- Establishment
- DAYTON GROUP, INC
- Site address
- 9000 COMMO ROAD BUILDING 101
- City
- CHELTENHAM
- State
- MD
- ZIP
- 20588
- Mailing
- 5523 RESEARCH PARK DRIVE SUITE 260, CATONSVILLE, MD 21228
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561210
- Employees
- 30
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $7981.00 · Current $6000.00 Reduced
General-duty citation text
29 CFR 1910.151(c):Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use. *A suitable eye wash must meet the minimum criteria as defined by ANSI/ISEA Z358.1. a) Firearms Building located at FLETC in Cheltenham, MD: on or about December 23, 2024, the employer did not have an eyewash station where employees are required to transfer D-Lead All Purpose Cleaner, which contains potassium hydroxide and is corrosive from a 55-gallon drum to a bucket.
Recent events (2)
- — I (O) $6000
- — Z (S) $7981
1910.1025 H01
- Issued
- Abate by
- Penalty
- Initial $7981.00 · Current $6000.00 Reduced
General-duty citation text
29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead. a) Firearms Building located at FLETC Cheltenham, in Cheltenham, MD - On or about December 23, 2024, wipe samples were taken of various surfaces within fire ranges 3, 5 and 6 where the fire ranges had been in use. The employees are responsible for cleaning the firing ranges after live exercises are completed. The wipe sample results ranged ranged from 27 - 573 micrograms of lead. b) Firearms Building located at FLETC Cheltenham, in Cheltenham, MD - On or about February 5, 2025 wipe samples were taken of various surfaces within fire ranges 5 and 7 where the fire ranges had been in use. The employees are responsible for cleaning the firing ranges after live exercises are completed. The wipe results ranged from 24.6 - 1857.3 micrograms of lead. c) Firearms Building located at FLETC Cheltenham, in Cheltenham, MD - On or about April 3, 2025 wipe samples were taken of various surfaces within fire ranges 1, 2, 4 and 7 where the fire ranges had been in use. The employees are responsible for cleaning the firing ranges after live exercises are completed. The wipe results ranged from 18.9 - 1120 micrograms of lead.
Recent events (2)
- — I (O) $6000
- — Z (S) $7981
More inspections in this industry (NAICS 561210)
DEDHAM, MA—2026-07-08
DEDHAM FACILITIES DEPARTMENT
HACKETTSTOWN, NJ—2026-07-07
TOWN OF HACKETTSTOWN DEPARTMENT OF PUBLIC WORKS
SALEM, VA—2026-07-02
ROANOKE COUNTY PUBLIC SCHOOLS
PEMBERTON, NJ—2026-07-02
TOWNSHIP OF PEMBERTON DPW
NEW GRETNA, NJ—2026-07-01
BASS RIVER TOWNSHIP DPW
More inspections in MD
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
CHESTERTOWN, MD—2026-07-15
WALLACE HENRY DISPOSAL, LLC
PARKVILLE, MD—2026-07-15
AMERICAN AUTOMATIC SPRINKLER COMPANY, INC.
PARKVILLE, MD—2026-07-15
THE POWER SOURCE, INC.
PARKVILLE, MD—2026-07-15
TEEL CONSTRUCTION, INC.
Source