Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DAYTON GROUP, INC

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of DAYTON GROUP, INC in 9000 COMMO ROAD BUILDING 101, CHELTENHAM, MD 20588 (NAICS 561210). OSHA activity number 347999260.

Watch Dayton Group, INC — free Get an email when a new federal OSHA severe-injury report for Dayton Group, INC is published. One employer, no account, unsubscribe in one click.
Establishment
DAYTON GROUP, INC
Site address
9000 COMMO ROAD BUILDING 101
City
CHELTENHAM
State
MD
ZIP
20588
Mailing
5523 RESEARCH PARK DRIVE SUITE 260, CATONSVILLE, MD 21228
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561210
Employees
30
Ownership type
A

2 citations on file for this inspection.

1910.151 C

Other-than-serious Gravity 5 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $7981.00 · Current $6000.00 Reduced
29 CFR  1910.151(c):Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use. *A suitable eye wash must meet the minimum criteria as defined by ANSI/ISEA Z358.1.  a) Firearms Building located at FLETC in Cheltenham, MD: on or about December 23, 2024, the employer did not have an eyewash station where employees are required to transfer D-Lead  All Purpose Cleaner, which contains potassium hydroxide and is corrosive from a 55-gallon drum to a bucket.
Recent events (2)
  • — I (O) $6000
  • — Z (S) $7981

1910.1025 H01

Other-than-serious Gravity 5 3 instances 30 exposed
Issued
Abate by
Penalty
Initial $7981.00 · Current $6000.00 Reduced
29 CFR  1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead.  a) Firearms Building located at FLETC Cheltenham, in Cheltenham, MD  - On or about December 23, 2024, wipe samples were taken of various surfaces within fire ranges 3, 5 and 6 where the fire ranges had been in use. The employees are responsible for cleaning the firing ranges after live exercises are completed. The wipe sample results ranged ranged from 27 - 573 micrograms of lead.  b) Firearms Building located at FLETC Cheltenham, in Cheltenham, MD  - On or about February 5, 2025 wipe samples were taken of various surfaces within fire ranges 5 and 7 where the fire ranges had been in use. The employees are responsible for cleaning the firing ranges after live exercises are completed. The wipe results ranged from 24.6 - 1857.3 micrograms of lead.  c) Firearms Building located at FLETC Cheltenham, in Cheltenham, MD  - On or about April 3, 2025 wipe samples were taken of various surfaces within fire ranges 1, 2, 4 and 7 where the fire ranges had been in use. The employees are responsible for cleaning the firing ranges after live exercises are completed. The wipe results ranged from 18.9 - 1120 micrograms of lead.