PEARLAND, TX —
OSHA Inspection: SOLVCHEM, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SOLVCHEM, INC. in 1904 MYKAWA ROAD, PEARLAND, TX 77581 (NAICS 424690). OSHA activity number 348001900.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOLVCHEM, INC.
- Site address
- 1904 MYKAWA ROAD
- City
- PEARLAND
- State
- TX
- ZIP
- 77581
- Mailing
- 1904 MYKAWA ROAD, PEARLAND, TX 77581
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424690
- Employees
- 120
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.119 E01
- Issued
- Jun 30, 2025
- Abate by
- Feb 20, 2026
- Penalty
- Initial $14,895 · Current $14,895
General-duty citation text
29 CFR 1910.119(e)(1): The employer did not perform an initial process hazard analysis (hazard evaluation) on processes covered by 29 CFR 1910.119 (a) On or about January 27, 2025, the employer did not conduct an initial process hazard analysis to address the hazards of processing flammable chemicals in the blending area.
Recent events (2)
- — I (S) $14895
- — Z (S) $14895
1910.119 F01 I D
- Issued
- Jun 30, 2025
- Abate by
- Feb 20, 2026
- Penalty
- Initial $14,895 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(f)(1)(i)(D): The employer did not develop and implement written operating procedures that provide clear instructions for emergency shutdown, including the conditions under which emergency shutdown is required, and the assignment of shutdown responsibility to qualified operators to ensure that emergency shutdown is executed in a safe and timely manner. (a) On or about January 27, 2025, in the blending area, the employer's operating procedure did not address emergency shutdown and conditions under which emergency shutdown is required.
Recent events (2)
- — I (S) $0
- — Z (S) $14895
1910.119 J02
- Issued
- Jun 30, 2025
- Abate by
- Feb 20, 2026
- Penalty
- Initial $14,895 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not establish written procedures to maintain the on-going integrity of process equipment. (a) On January 27, 2025, and at times prior, in the blending area, the employer did not establish written procedures to maintain the ongoing integrity of Blend Tank 400 used in the blending of flammable chemicals (b) On January 27, 2025, and at times prior, in the blending area, the employer did not establish written procedures to maintain the ongoing integrity of Blend Tank 100 used in the blending of flammable chemicals (c) On January 27, 2025, and at times prior, in the blending area, the employer did not establish written procedures to maintain the ongoing integrity of the process piping used for the transfer of chemicals from blending tanks.
Recent events (2)
- — I (S) $0
- — Z (S) $14895
More inspections at Solvchem, INC.
View Solvchem, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 424690)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348001900.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.