STATEN ISLAND, NY —
OSHA Inspection: M & R IMPROVEMENTS CORP.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of M & R IMPROVEMENTS CORP. in 20 ZEPHYR AVE., STATEN ISLAND, NY 10312 (NAICS 236115). OSHA activity number 348005851.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M & R IMPROVEMENTS CORP.
- Site address
- 20 ZEPHYR AVE.
- City
- STATEN ISLAND
- State
- NY
- ZIP
- 10312
- Mailing
- 143 VINELAND AVE., STATEN ISLAND, NY 10312
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Feb 19, 2025
- Penalty
- Initial $4,469 · Current $4,469
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). A) M & R Improvements Corp. - 20 Zephyr Ave., Staten Island NY 10312 - Employees were exposed to fall hazards of approx. 14' 7" above grade while conducting framing activities on residential construction with no fall protective measures in place. Occurred on January 28, 2025
Recent events (2)
- — I (S) $4469
- — Z (S) $4469
1926.1053 B01
- Issued
- Feb 19, 2025
- Penalty
- Initial $4,469 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. a) M & R Improvements Corp. - 20 Zephyr Ave., Staten Island NY 10312 - The employer did not ensure that the extension ladders used to access the upper levels extended at least 3 feet above the landing. this condition exposed employees to fall hazards of approx. 15' feet. Occurred on January 28, 2025
Recent events (2)
- — I (S) $0
- — Z (S) $4469
More inspections in this industry (NAICS 236115)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348005851.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.