OSHA Inspection: MCCLARIN PLASTICS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MCCLARIN PLASTICS in 15 INDUSTRIAL DRIVE, HANOVER, PA 17331 (NAICS 326199). OSHA activity number 348006503.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mcclarin Plastics — free Get an email when a new federal OSHA severe-injury report for Mcclarin Plastics is published. One employer, no account, unsubscribe in one click.
Establishment
MCCLARIN PLASTICS
Site address
15 INDUSTRIAL DRIVE
City
HANOVER
State
PA
ZIP
17331
Mailing
15 INDUSTRIAL DRIVE C/O CHIP LOUDERMILK, HANOVER, PA 17331
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
55
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 17, 2025
Abate by
Jul 15, 2025
Penalty
Initial $10,641 · Current $7,200 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:  (a) Big Comet Rotary Thermoformer - The Big Comet Rotary Thermoformer had electrical, gas, pneumatic, and thermal energy.  The employer had a machine-specific lockout/tagout procedure for this machine; however, this procedure only included electrical energy but did not include gas, compressed air, and residual heat as energy sources.  The machine-specific procedure did not include steps for how to de-energize and lockout/tagout the gas and compressed air nor did the procedure address the residual heat, on or about January 21, 2025.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $7200
  • — Z (S) $10641

1910.147 C06 I

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 17, 2025
Abate by
Jul 15, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   (a) Big Comet Rotary Thermoformer - The employer did not conduct an annual periodic inspection of the lockout/tagout procedure for the Big Comet Rotary Thermoformer, on or about January 29, 2025.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 17, 2025
Abate by
Jul 15, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employees did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:  (a) Big Comet Rotary Thermoformer - Not all employee who performed servicing and maintenance work (for example, machine set up) had received training as authorized employees, and these employee did not know of the need to lockout/tagout during set up, on or about January 29, 2025.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 17, 2025
Abate by
Jul 15, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:   (a) Big Comet Rotary Thermoformer - When doing set up, such as mold changes on the Big Comet Rotary Thermoformer, employees did not lockout/tagout the machine, on or about January 21, 2025.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Mcclarin Plastics's full OSHA safety record →