On , OSHA opened a planned safety inspection of JR METAL PRODUCTS, LLC in 52 HESS ROAD, LEOLA, PA 17540 (NAICS 332999). OSHA activity number 348009481.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JR Metal Products, LLC — free Get an email when a new federal OSHA severe-injury report for JR Metal Products, LLC is published. One employer, no account, unsubscribe in one click.
Site address
52 HESS ROAD
City
LEOLA
State
PA
ZIP
17540
Mailing
52 HESS ROAD, LEOLA, PA 17540
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
14
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 23, 2025
Penalty
Initial $3,215 · Current $3,215
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by pinch points.  a) 52 Hess Road LEOLA, PA 17540 - employees were operating a Cincinnati 25 shear (2510 SHEAR, number 35478) that did not have guarding to protect employees from pinch point and caught between hazards created by the material hold downs during the operating cycle, on or about January 30, 2025.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $3215

1910.242 B

Serious Gravity 5 4 instances 2 exposed
Issued
Apr 23, 2025
Abate by
May 19, 2025
Penalty
Initial $3,215 · Current $3,215
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.  a) 52 Hess Road LEOLA, PA 17540 - The compressed air blow guns used to clean metal shavings from, but not limited to, various CNC machines, was not reduced to 30 psi, on or about January 30, 2025.  b) 52 Hess Road LEOLA, PA 17540 - The compressed air blow guns used to clean metal shavings from, but not limited to, various CNC machines, was not equipped with a relief device to reduce the air pressure to less than 30 psi if the nozzle was dead-ended, on or about January 30, 2025.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $3215

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 23, 2025
Abate by
May 28, 2025
Penalty
Initial $3,215 · Current $3,215
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) 52 Hess Road LEOLA, PA 17540 - employees were performing service and maintenance activities including, but not limited to, setup, on equipment including, but not limited to, press brakes, shears, CNC machines, and saws, and the employer did not conduct periodic inspections of the energy control procedures at least annually, on or about January 30, 2025.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $3215

1910.147 C07 I A

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 23, 2025
Abate by
May 28, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.   a)  52 Hess Road LEOLA, PA 17540 - employees were performing service and maintenance activities including, but not limited to, setup, on equipment including, but not limited to, press brakes, shears, CNC machines, and saws, and the employer did not conduct authorized employee training, on or about January 30, 2025.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

View JR Metal Products, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348009481.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.