Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CRISTIAN FERNANDO VIDAL MARTINEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CRISTIAN FERNANDO VIDAL MARTINEZ in 3106 MORRIS HILL DR, LOT 10, DACULA, GA 30019 (NAICS 238130). OSHA activity number 348010349.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cristian Fernando Vidal Martinez — free Get an email when a new federal OSHA severe-injury report for Cristian Fernando Vidal Martinez is published. One employer, no account, unsubscribe in one click.
Site address
3106 MORRIS HILL DR, LOT 10
City
DACULA
State
GA
ZIP
30019
Mailing
4649 PEACHTREE INDUSTRIAL BLVD APT H, ATLANTA, GA 30360
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 5 exposed
Issued
Mar 19, 2025
Penalty
Initial $1,809 · Current $1,809
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:  a) Lot #10: On or about January 29, 2025, the employer exposed employees to struck-by hazards while operating pneumatic framing nail guns, in that protective eyewear was not provided to employees while operating nail guns at 100 PSI engaged in framing activities.
Recent events (1)
  • — Z (S) $1809

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 19, 2025
Penalty
Initial $2,412 · Current $2,412
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:   a) Lot #10,Top plate: On or about January 29, 2025,  the employer exposed employees to fall hazards of approximately 21 feet to the lower level, in that a fall protection system was not provided to employees engaged in framing activities using the top plate as a walking/working surface.
Recent events (1)
  • — Z (S) $2412

1926.1053 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 19, 2025
Penalty
Initial $2,837 · Current $2,837
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) Lot #10, Stairwell: On or about January 29, 2025, the employer exposed employees to fall hazards of up to 11-feet to the lower level, in that the ladder provided did not have siderails which extended at least 3-feet to allow for safe access to each level.
Recent events (1)
  • — Z (S) $2837

1926.403 B01

Other-than-serious 1 instance 5 exposed
Issued
Mar 19, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:   a) Lot #10, On or about January 29, 2025, the employer failed to inspect all electrical extension cords used to provide power to electric tools employees engaged in framing operations were using, in that the orange extension cord powering the DeWalt reciprocating, circular saw, and battery charger, was damaged. An inspection of these cords was not performed prior to the shift as these cords were not repaired or removed from service.
Recent events (1)
  • — Z (O) $0

1926.404 F06

Other-than-serious 1 instance 5 exposed
Issued
Mar 19, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  a) Lot #10, On or about January 29, 2025, the employer exposed employees to 120V electrical shock hazards while operating a DeWalt reciprocating, circular saw, and battery charger, in that the yellow extension cord was missing the grounding pin.
Recent events (1)
  • — Z (O) $0

View Cristian Fernando Vidal Martinez's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348010349.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.