SAN DIEGO, CA —
OSHA Inspection: NAVAL BASE POINT LOMA- SECURITY FORCES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NAVAL BASE POINT LOMA- SECURITY FORCES in BLDG 158, SAN DIEGO, CA 92106 (NAICS 922120). OSHA activity number 348010539.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NAVAL BASE POINT LOMA- SECURITY FORCES
- Site address
- BLDG 158
- City
- SAN DIEGO
- State
- CA
- ZIP
- 92106
- Mailing
- 140 SYLVESTER RD, SAN DIEGO, CA 92106
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 922120
- Employees
- 40
- Ownership type
- D
Citations
3 citations on file for this inspection.
1910.303 B02
- Issued
- Feb 19, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about January 29, 2025, and at times prior thereto, electrical equipment such as coffee makers, microwaves, and refrigerators were not used in accordance with instructions included in the listing or labeling. In the following locations: a) 2nd deck, 204, training breakroom area, a Keurig coffee maker, Cuisinart coffee maker, and Honeywell toaster oven were plugged into an NDE- Current TAP model MD-706B. b) 2nd deck, cubical adjacent to breakroom area, a ceramic heater model PTC-SH009 was connected to a relocatable power tap. This condition potentially exposed employee(s) to electrical shock an/or fire hazard(s).
Recent events (1)
- — Z (S) $0
1910.303 G01 II
- Issued
- Feb 19, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: 2nd floor A/C HVAC Room: On and/or before January 29, 2025, the employer did not ensure at least 3 feet in front of the switch box was clear. The switch box had a box and CPR gear obstructing the panel. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).
Recent events (1)
- — Z (S) $0
1910.38 C04
- Issued
- Feb 19, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.38(c)(4): The employer's emergency action plan did not include procedures to account for all employees after evacuation. Bldg. 158: On and/or before January 29, 2025, the employer's emergency action plan did not include procedures to account for all employee(s) after an evacuation has been made. This condition potentially exposes employee(s) to fire hazard(s).