SAINT AUGUSTINE, FL ·
OSHA Inspection: TERRA ENERGY SOLAR, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TERRA ENERGY SOLAR, LLC. in 823 CORDOVA PALMS, SAINT AUGUSTINE, FL 32080 (NAICS 221114). OSHA activity number 348010612.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TERRA ENERGY SOLAR, LLC.
- Site address
- 823 CORDOVA PALMS
- City
- SAINT AUGUSTINE
- State
- FL
- ZIP
- 32080
- Mailing
- 2085 NW 2 ND AVENUE, MIAMI, FL 33127
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221114
- Employees
- 4
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.102 A01
- Issued
- Mar 28, 2025
- Penalty
- Initial $4,965 · Current $2,979 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids, caustic liquids, or chemical gases or vapors and at times prior thereto, workers were exposed to a struck by hazard while cutting concrete with a saw, without the use and wear of protective eyewear: a. At a residential construction north side located at 823 Cordova Palms St. Agustine FL. On or about January 30, 2025, the employer exposed employees to struck-by hazards, in that protective eyewear was not utilized by employees while using impact drivers for solar panel installation.
Recent events (2)
- · I (S) $2979
- · Z (S) $4965
1926.501 B13
- Issued
- Mar 28, 2025
- Penalty
- Initial $8,276 · Current $4,966 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. At a residential construction north side located at 823 Cordova Palms St. Agustine FL. On or about January 30, 2025, the employer was exposing 3 employees to a 9 1/2-foot fall hazard, in that the employees were not wearing fall protection when installing solar panels.
Recent events (2)
- · I (S) $4965.6
- · Z (S) $8276
More inspections in this industry (NAICS 221114)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348010612.