MELBOURNE, FL —
OSHA Inspection: DAB PAINTING OF BREVARD, INC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of DAB PAINTING OF BREVARD, INC in 2716 CYCARD LN., MELBOURNE, FL 32940 (NAICS 238320). OSHA activity number 348017120.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DAB PAINTING OF BREVARD, INC
- Site address
- 2716 CYCARD LN.
- City
- MELBOURNE
- State
- FL
- ZIP
- 32940
- Mailing
- 508 ADAMS AVE, CAPE CANAVERAL, FL 32920
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 5
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 C02
- Issued
- Apr 30, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates and mud sills or other adequate firm foundation: a) On or about January 31, 2025, at the job site, Lot 2 Block D: subcontractor employees were exposed to an approximate 7-foot (first tier) fall hazard while working on a scaffold to conduct painting operations, in that, the scaffold support poles were not resting on a mud sill, base plate or other adequate foundation. b) On or about January 31, 2025, at the job site, Lot 2 Block D: subcontractor employees were exposed to an approximate 14-foot (second tier) fall hazard while working on a scaffold to conduct painting operations, in that, the scaffold support poles were not resting on a mud sill, base plate or other adequate foundation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Apr 30, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access. a) On or about January 31, 2025, Lot 2 Block D: subcontractor employees were exposed to an approximate 7 foot fall (first tier) hazard while working on a scaffold to conduct painting operations, in that, safe access was not provided. b) On or about January 31, 2025, Lot 2 Block D: subcontractor employees were exposed to an approximate 14 foot fall (second tier) hazard while working on a scaffold to conduct painting operations, in that, safe access was not provided.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F03
- Issued
- Apr 30, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(3):Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) On or about January 31, 2025, at the job site, Lot 2 Block D: subcontractor employees were to an approximate 7-foot fall hazard (first tier) while working on a scaffold to conduct painting operations, in that, scaffold components were not inspected for visible defects by a competent person before each work shift. b) On or about January 31, 2025, at the job site, Lot 2 Block D: subcontractor employees were to an approximate 14-foot fall hazard (second tier) while working on a scaffold to conduct painting operations, in that, scaffold components were not inspected for visible defects by a competent person before each work shift.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Apr 30, 2025
- Penalty
- Initial $4,469 · Current $2,681 Reduced
General-duty citation text
29 CFR 1926.451(g)(1):Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) On or about January 31, 2025, Lot 2 Block D: subcontractor employees were exposed to an approximate 14-foot (second tier) fall hazard while working on a scaffold to conduct painting operations, in that, fall protection was not used.
Recent events (2)
- — I (S) $2681.4
- — Z (S) $4469
1926.451 B01
- Issued
- Apr 30, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is no. a) On or about January 31, 2025, at the job site: subcontractor employees were exposed to an approximate 7-foot (first tier) fall hazard while working on a scaffold to conduct painting operations, in that, the working platform was not fully planked. b) On or about January 31, 2025, at the job site: subcontractor employees were exposed to an approximate 14-foot (second tier) fall hazard while working on a scaffold to conduct painting operations, in that, the working platform was not fully planked.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.454 A
- Issued
- Apr 30, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) On or about January 31, 2025, Lot 2 Block D: subcontractor employees were exposed to an approximate 7 foot (first tier) fall hazard while working on a scaffold to conduct painting operations, in that, scaffold training was not provided. b) On or about January 31, 2025, Lot 2 Block D: subcontractor employees were exposed to an approximate 14 foot (second tier) fall hazard while working on a scaffold to conduct painting operations, in that, scaffold training was not provided.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Apr 30, 2025
- Penalty
- Initial $3,192 · Current $1,915 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about January 31, 2025, Lot 2 Block D: subcontractor employees were exposed to an approximate 10 foot fall hazard while preparing a house for painting on a 5:12 pitched roof, in that, fall protection was not used.
Recent events (2)
- — I (S) $1915.2
- — Z (S) $3192
More inspections in this industry (NAICS 238320)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348017120.