Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALCAST, LLC DBA ALCAST COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ALCAST, LLC DBA ALCAST COMPANY in 8821 N UNIVERSITY ST, PEORIA, IL 61615 (NAICS 331523). OSHA activity number 348019993.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alcast, LLC DBA Alcast Company — free Get an email when a new federal OSHA severe-injury report for Alcast, LLC DBA Alcast Company is published. One employer, no account, unsubscribe in one click.
Site address
8821 N UNIVERSITY ST
City
PEORIA
State
IL
ZIP
61615
Mailing
8821 N UNIVERSITY ST, PEORIA, IL 61615
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331523
Employees
300
Ownership type
A

2 citations on file for this inspection.

1910.242 A

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 13, 2025
Penalty
Initial $11,055 · Current $7,000 Reduced
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition:  Employees of Alcast, LLC dba Alcast Company were exposed to the hazard of being severely burned by molten aluminum being ejected from the melting furnace when moisture was present on the dipping ladles. Employees were required to transfer molten aluminum from the melting furnace to the holding furnace using steel ladles coated in a water-based ladle wash.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $11055

1910.303 G01 I A

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Jun 13, 2025
Penalty
Initial $7,516 · Current $4,143 Reduced
29 CFR 1910.303(g)(1)(i)(A):  For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:  On or about February 4, 2025, employees in the Foundry Department were exposed to injury and not able to access the E-1 WEST and E-1 EAST electric panels due to stored equipment blocking the panels.