VIDOR, TX —
OSHA Inspection: J-3 METALS RECYCLING CENTER, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of J-3 METALS RECYCLING CENTER, LLC in 6755 N HWY 105, VIDOR, TX 77662 (NAICS 331491). OSHA activity number 348024050.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J-3 METALS RECYCLING CENTER, LLC
- Site address
- 6755 N HWY 105
- City
- VIDOR
- State
- TX
- ZIP
- 77662
- Mailing
- 6755 N HWY 105, VIDOR, TX 77662
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331491
- Employees
- 40
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.147 C01
- Issued
- Apr 1, 2025
- Abate by
- Apr 11, 2025
- Penalty
- Initial $8,276 · Current $8,276
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On or about January 29, 2025, at the metal recycling facility, where the employer did not develop an energy control program for employees that perform maintenance and servicing activities such as cleaning and removing recycling debris on conveyor system parts and equipment.
Recent events (1)
- — Z (S) $8276
1910.147 C04 I
- Issued
- Apr 1, 2025
- Abate by
- Apr 11, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about January 29, 2025, at the metal recycling facility, where the employer did not develop procedures to control the energy sources provided to the motors and pullies on a conveyor system before employees cleaned and removed recycling debris.
Recent events (1)
- — Z (S) $0
1910.219 D01
- Issued
- Apr 1, 2025
- Abate by
- Apr 24, 2025
- Penalty
- Initial $8,276 · Current $8,276
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) On or about January 29, 2025, on conveyor #2, where employees cleaned and removed recycling debris around an unguarded tail pulley.
Recent events (1)
- — Z (S) $8276
1910.219 E03 I
- Issued
- Apr 1, 2025
- Abate by
- Apr 24, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a) On or about January 29, 2025, on conveyor #2, where employees cleaned and removed recycling debris around an unguarded inclined belt on a conveyor.
Recent events (1)
- — Z (S) $0
1910.303 B07 IV
- Issued
- Apr 1, 2025
- Abate by
- Apr 11, 2025
- Penalty
- Initial $6,620 · Current $6,620
General-duty citation text
29 CFR 1910.303(b)(7)(iv): Electrical equipment was not free of damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: a) On or about February 5, 2025, at the metal recycling facility, where electrical equipment, such as an electrical enclosure and conduit, were damaged by recycled metal debris.
Recent events (1)
- — Z (S) $6620
1910.303 E01 II
- Issued
- Apr 1, 2025
- Abate by
- Apr 11, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(e)(1)(ii): Electrical equipment was used when the markings giving voltage, current, wattage, or other ratings as necessary were missing: a) On or about February 5, 2025, at a metal recycling facility, where an electrical enclosure was not labeled with its voltage, current, and wattage.
Recent events (1)
- — Z (S) $0
1910.145 C02 I
- Issued
- Apr 1, 2025
- Abate by
- Apr 11, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.145(c)(2)(i): Caution signs were not used to warn against potential hazards or to caution against unsafe practices: a) On or about February 5, 2025, on conveyor 2, where signs were not used to warn employees about the hazards of rotating parts on a tail pulley.
Recent events (1)
- — Z (O) $0
1910.145 E02
- Issued
- Apr 1, 2025
- Abate by
- Apr 11, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.145(e)(2): The wording of signs was not easily read and concise: a) On or about February 5, 2025, on conveyor 2, where the caution and warning labels on an electrical enclosure were worn, faded, and illegible.
Recent events (1)
- — Z (O) $0
1910.305 B02 I
- Issued
- Apr 1, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a) On or about January 29, 2025, in the metal recycling facility operator room, where a conduit body with live conductors was not covered.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 331491)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348024050.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.