ROCKAWAY, NJ —
OSHA Inspection: J.E.R MASONRY LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of J.E.R MASONRY LLC in 34 WEST MAIN STREET, ROCKAWAY, NJ 07866 (NAICS 238140). OSHA activity number 348031667.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J.E.R MASONRY LLC
- Site address
- 34 WEST MAIN STREET
- City
- ROCKAWAY
- State
- NJ
- ZIP
- 07866
- Mailing
- 142 SPRING STREET, LEONIA, NJ 07605
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 C02
- Issued
- May 23, 2025
- Penalty
- Initial $4,965 · Current $5,000
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. a) 42 West Main Street Rockaway NJ: Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and/or mud sills or other adequate firm foundation, on or about 2/7/25 -
Recent events (3)
- — F (S) $5000
- — C (S) $4965
- — Z (S) $4965
1926.451 E01
- Issued
- May 23, 2025
- Penalty
- Initial $4,965 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(e)(1):scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. a) Tubular welded pipe scaffold: Employee were exposed to a fall hazard while a means of access was not provided. Employees were using the frames and crossbraces as a means of access, on or about 2/7/25
Recent events (3)
- — F (S) $0
- — C (S) $4965
- — Z (S) $4965
1926.451 B01
- Issued
- May 23, 2025
- Penalty
- Initial $4,965 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(1):29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports: a) pipe scaffold: Employees were exposed to fall hazard while working on a pipe scaffold that all working levels were not full planked or deck between the front and uprights, on or about 2/7/25.
Recent events (3)
- — F (S) $0
- — C (S) $4965
- — Z (S) $4965
More inspections in this industry (NAICS 238140)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348031667.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.