PENSACOLA, FL —
OSHA Inspection: FLUID METALWORKS, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of FLUID METALWORKS, INC. in 55 SOUTH A STREET, PENSACOLA, FL 32502 (NAICS 332312). OSHA activity number 348033598.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLUID METALWORKS, INC.
- Site address
- 55 SOUTH A STREET
- City
- PENSACOLA
- State
- FL
- ZIP
- 32502
- Mailing
- 55 SOUTH A STREET, PENSACOLA, FL 32502
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 25
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.253 B04
- Issued
- Jun 24, 2025
- Abate by
- Jul 16, 2025
- Penalty
- Initial $3,405 · Current $2,043 Reduced
2150X100
General-duty citation text
29 CFR 1910.253(b)(4): Oxygen cylinders in storage were not separated from fuel gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour: a) Gas Cylinder Storage Area: On or about February 18, 2025, and at times prior to, the employer exposed employee(s) to full compressed oxygen cylinders being stored near full fuel-gas acetylene and propane cylinders.
Recent events (2)
- — I (S) $2043
- — Z (S) $3405
1910.134 C02 II
- Issued
- Jun 24, 2025
- Abate by
- Jul 16, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(ii):The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) Welding Fabrication Shop: On or about February 10, 2025, and at times prior to, the employer provided to the employees tight fitting respirators for voluntary use and did not implement elements of a written program for all employees assigned a tight-fitting respirator.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 F02
- Issued
- Jun 24, 2025
- Abate by
- Jul 16, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2):Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: Welding Fabrication Shop: On or about February 10, 2025, and at times prior to, the employer provided employees half mask tight fitting respirators with particulate filters for voluntary use and did not ensure employees were fit tested prior to initial use.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 K06
- Issued
- Jun 24, 2025
- Abate by
- Jul 16, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6):The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: a) Welding Fabrication Shop: On or about February 10, 2025, and at times prior to, the employer provided employees half mask tight fitting respirators with particulate filters for voluntary use and did not train employees on respirator use, care, and limitations.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01 I
- Issued
- Jun 24, 2025
- Abate by
- Jul 16, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1)(i):The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet. a) Facility wide: On or about February 10, 2025, and at times prior to, the employer did not create a list of chemicals used on site prior to assigning employees to work with various chemicals.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F06 II
- Issued
- Jun 24, 2025
- Abate by
- Jul 16, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: a) Welding Fabrication Shop Area: On or about February 10, 2024, and at times prior to, the employer did not ensure all secondary containers were labeled with the hazards associated with the chemical in use.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 G08
- Issued
- Jun 24, 2025
- Abate by
- Jul 16, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s). a) Facility wide: On or about February 10, 2025, and at times prior to, the employer did not have readily available safety data sheets for all chemicals in use on the site prior to assigning work with those chemicals such as compressed gases.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Fluid Metalworks, INC.
View Fluid Metalworks, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348033598.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.