Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RYCHTIK WELDING & MANUFACTURING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of RYCHTIK WELDING & MANUFACTURING, INC. in 818 BEECH STREET, GRAFTON, WI 53024 (NAICS 333992). OSHA activity number 348034331.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rychtik Welding & Manufacturing, INC. — free Get an email when a new federal OSHA severe-injury report for Rychtik Welding & Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
818 BEECH STREET
City
GRAFTON
State
WI
ZIP
53024
Mailing
818 BEECH STREET, GRAFTON, WI 53024
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333992
Employees
10
Ownership type
A

3 citations on file for this inspection.

1910.334 A02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 20, 2025
Abate by
Jul 2, 2025
Penalty
Initial $1,809 · Current $1,266 Reduced
29 CFR  1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  (a) On or about February 11, 2025, employees utilized damaged flexible cords to power the handheld grinders being used on site. This exposed employees to potential electrical shock hazard.
Recent events (2)
  • — I (S) $1266.3
  • — Z (S) $1809

1910.334 A02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 20, 2025
Abate by
Jul 2, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made:  (a) On or about February 11, 2025, employees utilized damaged flexible cords to power the handheld grinders being used on site. This exposed employees to potential electrical shock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L06

Other-than-serious 1 instance 1 exposed
Issued
Jun 20, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(6):The certification did not include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation:  (a) On or about February 11, 2025, an employee operated a forklift to move materials throughout the facility and the employer failed to ensure their forklift training was certified.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348034331.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.